6.6.2.5 Management Frame Register Address
6.6.2.6 Management Frame Operational Code
6.6.2.7 Management Frame Turnaround
6.6.2.8 Management Frame Data
6.6.2.9 Serial Management Interface Idle State
ICS1893CK-40, Rev. C, 06/02/09
Upon receiving a valid STA transaction, during a power-on or hardware reset an ICS1893CK-40 compares
the PHYAD field included within the management frame with the value of its PHYAD bits stored in register
16. (For information on the PHYAD bits, see
that match its stored address bits.
A Management Frame includes a 5-bit register address field, REGAD. This field identifies which of the 32
Management Registers are involved in a transaction between an STA and a PHY.
A management frame includes a 2-bit operational code field, OP. If the operation code is a:
A valid management frame includes a turn-around field (TA), which is a 2-bit time space between the
REGAD field and the Data field. This time allows an ICS1893CK-40 and an STA to avoid contentions
during read transactions. During an operation that is a:
A valid management frame includes a 16-bit Data field for exchanging the register contents between the
ICS1893CK-40 and the STA. All Management Registers are 16 bits wide, matching the width of the Data
field. During a transaction that is a:
If the STA attempts to:
Note:
The MDIO signal is in an idle state during the time between STA transactions. When the Serial
Management Interface is in the idle state, the ICS1893CK-40 disables (that is, tri-states) its MDIO pin,
which enters a high-impedance state. The ISO/IEC 8802-3 standard requires that an MDIO signal be idle
for at least one bit time between management transactions. However, the ICS1893CK-40 does not have
this limitation and can support a continual bit stream on its MDIO signals.
Read, the REGAD field identifies the register used as the source of data returned to the STA by the
ICS1893CK-40.
Write, the REGAD identifies the destination register that is to receive the data sent by the STA to the
ICS1893CK-40.
Read, an ICS1893CK-40 remains in the high-impedance state during the first bit time and subsequently
drives its MDIO pin to logic zero for the second bit time.
Write, an ICS1893CK-40 waits while the STA transmits a logic one, followed by a logic zero on its MDIO
pin.
Read, (OP is 10b) the ICS1893CK-40 obtains the contents of the register identified in the REGAD field
and returns this Data to the STA synchronously with its MDC signal.
Write, (OP is 01b) the ICS1893CK-40 stores the value of the Data field in the register identified in the
REGAD field.
Read from a non-existent ICS1893CK-40 register, the ICS1893CK-40 returns logic one for all bits in the
Data field, FFFFh.
Write to a non-existent ICS1893CK-40 register, the ICS1893CK-40 isolates the Data field of the
management frame from every reaching the registers.
The first Data bit transmitted and received is the most-significant bit of a Management Register, bit
X.15.
ICS1893CK-40 Data Sheet Rev. C - Release
Copyright © 2009, Integrated Device Technology, Inc.
Table
All rights reserved.
41
7-16.) An ICS1893CK-40 responds to all transactions
Chapter 6 Functional Blocks
June 2009