IDT7005L35G IDT, Integrated Device Technology Inc, IDT7005L35G Datasheet - Page 18

no-image

IDT7005L35G

Manufacturer Part Number
IDT7005L35G
Description
IC SRAM 64KBIT 35NS 68PGA
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT7005L35G

Format - Memory
RAM
Memory Type
SRAM - Dual Port, Asynchronous
Memory Size
64K (8K x 8)
Speed
35ns
Interface
Parallel
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Package / Case
68-PGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
7005L35G

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT7005L35G
Manufacturer:
IDT
Quantity:
2 399
Part Number:
IDT7005L35G
Manufacturer:
MOT
Quantity:
125
Part Number:
IDT7005L35G
Manufacturer:
IDT
Quantity:
286
Part Number:
IDT7005L35GB
Manufacturer:
INTERSIL
Quantity:
1 520
Part Number:
IDT7005L35GB
Manufacturer:
IDT
Quantity:
200
configurations. The IDT7005 does not use its semaphore flags to control
any resources through hardware, thus allowing the system designer total
flexibility in system architecture.
methods of hardware arbitration is that wait states are never incurred in
either processor. This can prove to be a major advantage in very
How the Semaphore Flags Work
of the Dual-Port RAM. These latches can be used to pass a flag, or token,
from one port to the other to indicate that a shared resource is in use. The
semaphores provide a hardware assist for a use assignment method
called “Token Passing Allocation.” In this method, the state of a semaphore
latch is used as a token indicating that shared resource is in use. If the left
processor wants to use this resource, it requests the token by setting the
latch. This processor then verifies its success in setting the latch by reading
it. If it was successful, it proceeds to assume control over the shared
resource. If it was not successful in setting the latch, it determines that the
right side processor has set the latch first, has the token and is using the
shared resource. The left processor can then either repeatedly request
that semaphore’s status or remove its request for that semaphore to perform
another task and occasionally attempt again to gain control of the token via
the set and test sequence. Once the right side has relinquished the token,
the left side should succeed in gaining control.
a zero into a semaphore latch and is released when the same side writes
a one to that latch.
memory space from the Dual-Port RAM. This address space is accessed
by placing a LOW input on the SEM pin (which acts as a chip select for the
semaphore flags) and using the other control pins (Address, OE, and
R/W) as they would be used in accessing a standard static RAM. Each
of the flags has a unique address which can be accessed by either side
through address pins A
the other address pins has any effect.
is written into an unused semaphore location,that flag will be set to a zero
on that side and a one on the other side (see Truth Table V). That
semaphore can now only be modified by the side showing the zero. When
a one is written into the same location from the same side, the flag will be
set to a one for both sides (unless a semaphore request from the other side
is pending) and then can be written to by both sides. The fact that the side
which is able to write a zero into a semaphore subsequently locks out writes
from the other side is what makes semaphore flags useful in interprocessor
communications. (A thorough discussion on the use of this feature follows
shortly.) A zero written into the same location from the other side will be
stored in the semaphore request latch for that side until the semaphore is
freed by the first side.
that a flag that is a one reads as a one in all data bits and a flag containing
a zero reads as all zeros. The read value is latched into one side’s output
register when that side's semaphore select (SEM) and output enable (OE)
signals go active. This serves to disallow the semaphore from changing
state in the middle of a read cycle due to a write cycle from the other side.
Because of this latch, a repeated read of a semaphore in a test loop must
high-speed systems.
IDT7005S/L
High-Speed 8K x 8 Dual-Port Static RAM
An advantage of using semaphores rather than the more common
The semaphore logic is a set of eight latches which are independent
The semaphore flags are active LOW. A token is requested by writing
The eight semaphore flags reside within the IDT7005 in a separate
When writing to a semaphore, only data pin D
When a semaphore flag is read, its value is spread into all data bits so
0
– A
2
. When accessing the semaphores, none of
0
is used. If a LOW level
6.42
18
cause either signal (SEM or OE) to go inactive or the output will
never change.
to guarantee that no system level contention will occur. A processor
requests access to shared resources by attempting to write a zero into a
semaphore location. If the semaphore is already in use, the semaphore
request latch will contain a zero, yet the semaphore flag will appear as one,
a fact which the processor will verify by the subsequent read (see Truth
Table V). As an example, assume a processor writes a zero to the left port
at a free semaphore location. On a subsequent read, the processor will
verify that it has written successfully to that location and will assume control
over the resource in question. Meanwhile, if a processor on the right side
attempts to write a zero to the same semaphore flag it will fail, as will be
verified by the fact that a one will be read from that semaphore on the right
side during subsequent read. Had a sequence of READ/WRITE been
used instead, system contention problems could have occurred during the
gap between the read and write cycles.
by either repeated reads or by writing a one into the same location. The
reason for this is easily understood by looking at the simple logic diagram
of the semaphore flag in Figure 4. Two semaphore request latches feed
into a semaphore flag. Whichever latch is first to present a zero to the
semaphore flag will force its side of the semaphore flag LOW and the other
side HIGH. This condition will continue until a one is written to the same
semaphore request latch. Should the other side’s semaphore request latch
have been written to a zero in the meantime, the semaphore flag will flip
over to the other side as soon as a one is written into the first side’s request
latch. The second side’s flag will now stay LOW until its semaphore request
latch is written to a one. From this it is easy to understand that, if a semaphore
is requested and the processor which requested it no longer needs the
resource, the entire system can hang up until a one is written into that
semaphore request latch.
single token by attempting to write a zero into it at the same time. The
semaphore logic is specially designed to resolve this problem. If simulta-
neous requests are made, the logic guarantees that only one side receives
the token. If one side is earlier than the other in making the request, the
first side to make the request will receive the token. If both requests arrive
at the same time, the assignment will be arbitrarily made to one port or
semaphores alone do not guarantee that access to a resource is secure.
As with any powerful programming technique, if semaphores are misused
or misinterpreted, a software error can easily happen.
via the initialization program at power-up. Since any semaphore request
flag which contains a zero must be reset to a one, all semaphores on both
sides should have a one written into them at initialization from both sides
to assure that they will be free when needed.
Using Semaphores—Some Examples
resource markers for the IDT7005’s Dual-Port RAM. Say the 8K x 8 RAM
was to be divided into two 4K x 8 blocks which were to be dedicated at any
one time to servicing either the left or right port. Semaphore 0 could be used
to indicate the side which would control the lower section of memory, and
the other.
A sequence WRITE/READ must be used by the semaphore in order
It is important to note that a failed semaphore request must be followed
The critical case of semaphore timing is when both sides request a
One caution that should be noted when using semaphores is that
Initialization of the semaphores is not automatic and must be handled
Perhaps the simplest application of semaphores is their application as
Military, Industrial and Commercial Temperature Ranges