TLE5206-2 Infineon Technologies, TLE5206-2 Datasheet - Page 6

IC H-BRIDGE 5A DC MOTOR TO220-7

TLE5206-2

Manufacturer Part Number
TLE5206-2
Description
IC H-BRIDGE 5A DC MOTOR TO220-7
Manufacturer
Infineon Technologies
Type
H-Bridge for DC Motor Applicationr
Datasheets

Specifications of TLE5206-2

Package / Case
TO-220-7 (Bent and Staggered Leads)
Applications
DC Motor Driver, H Bridge
Number Of Outputs
1
Current - Output
±5A
Voltage - Supply
5.3 V ~ 40 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Through Hole
Operating Supply Voltage
- 0.3 V to + 40 V
Supply Current
6 A
Mounting Style
Through Hole
Packages
PG-TO220-7
Current Limit (min.)
6.0 A
Rthjc (max)
3.0 K/W
Quiescent Current (max.)
10 mA
Operating Range
6 - 40 V
Rds (on) (typ./switch)
220.0 mOhm
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Voltage - Load
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
SP000011892
TLE5206-2
TLE5206-2IN
TLE52062
TLE52062NK

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE5206-2
Manufacturer:
INFINEON
Quantity:
12 500
Part Number:
TLE5206-2
Manufacturer:
INF
Quantity:
20 000
Part Number:
TLE5206-2G
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
TLE5206-2GP
Manufacturer:
INFINEON
Quantity:
6
Part Number:
TLE5206-2GP
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
TLE5206-2S
Manufacturer:
NXP
Quantity:
5 000
Part Number:
TLE5206-2S
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
1.7
Undervoltage lockout (UVLO):
When
All output transistors are switched off if the supply voltage
value
1.8
Various errors like short-circuit to +
result in turn-OFF of the output stages after a delay of 50 s and setting of the error flag
EF to ground. Changing the inputs resets the error flag.
a. Output Shorted to Ground Detection
b. Output Shorted to +
c. Overload Detection
d. Overtemperature Protection
Data Sheet
If a high side transistor is switched on and its output is shorted to ground, the output
current is internally limited. After a delay of 50 s all outputs will be switched-OFF and
the error flag is set.
If a low side transistor is switched on and its output is shorted to the supply voltage,
the output current is internally limited. After a delay of 50
switched-OFF and the error flag is set.
An internal circuit detects if the current through the low side transistor exceeds the
trippoint
At a junction temperature higher than 150 C the thermal shutdown turns-OFF, all four
output stages commonly and the error flag is set with a delay.
V
V
S OFF.
S
Monitoring Functions
Protective Function
reaches the switch on voltage
I
SDL
. In this case all outputs are turned off after 50 s and the error flag is set.
V
S
Detection
V
S
, ground or across the load are detected. All faults
V
S ON
6
the IC becomes active with a hysteresis.
V
S
drops below the switch off
s all outputs will be
TLE 5206-2
2001-06-19
Overview

Related parts for TLE5206-2