MPC564EVB Freescale Semiconductor, MPC564EVB Datasheet - Page 484

KIT EVAL FOR MPC561/562/563/564

MPC564EVB

Manufacturer Part Number
MPC564EVB
Description
KIT EVAL FOR MPC561/562/563/564
Manufacturer
Freescale Semiconductor
Type
Microcontrollerr
Datasheets

Specifications of MPC564EVB

Contents
Module Board, Installation Guide, Power Supply, Cable, Software and more
Processor To Be Evaluated
MPC56x
Data Bus Width
32 bit
Interface Type
RS-232, Ethernet
For Use With/related Products
MPC561, 562, 563, 564
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
QADC64E Legacy Mode Operation
Each time a CCW is read for queue 1, the CCW location is compared with the current value of the BQ2
pointer to detect a possible end-of-queue condition. For example, if BQ2 is changed to CCW3 while queue
1 is converting CCW2, queue 1 is terminated after the conversion is completed. However, if BQ2 is
changed to CCW1 while queue 1 is converting CCW2, the QADC64E would not recognize a BQ2
end-of-queue condition until queue 1 execution reached CCW1 again, presumably on the next pass
through the queue.
13.3.8
The status registers contains information about the state of each queue and the current A/D conversion.
Except for the four flag bits (CF1, PF1, CF2, and PF2) and the two trigger overrun bits (TOR1 and TOR2),
13-20
Status Registers (QASR0 and QASR1)
If BQ2 was assigned to the CCW that queue 1 is currently working on, then
that conversion is completed before BQ2 takes effect.
MQ2[3:7]
01011
01100
01101
01110
01111
10000
10001
10010
10011
10100
10101
10110
10111
11000
11001
11010
11011
11100
11101
11110
11111
Table 13-13. Queue 2 Operating Modes (continued)
Interval timer single-scan mode: time = QCLK period x 2
Interval timer single-scan mode: time = QCLK period x 2
Interval timer single-scan mode: time = QCLK period x 2
Interval timer single-scan mode: time = QCLK period x 2
Reserved mode
Reserved mode
Software triggered continuous-scan mode
External trigger rising edge continuous-scan mode
External trigger falling edge continuous-scan mode
Periodic timer continuous-scan mode: time = QCLK period x 2
Periodic timer continuous-scan mode: time = QCLK period x 2
Periodic timer continuous-scan mode: time = QCLK period x 2
Periodic timer continuous-scan mode: time = QCLK period x 2
Periodic timer continuous-scan mode: time = QCLK period x 2
Periodic timer continuous-scan mode: time = QCLK period x 2
Periodic timer continuous-scan mode: time = QCLK period x 2
Periodic timer continuous-scan mode: time = QCLK period x 2
Periodic timer continuous-scan mode: time = QCLK period x 2
Periodic timer continuous-scan mode: time = QCLK period x 2
Periodic timer continuous-scan mode: time = QCLK period x 2
Reserved mode
MPC561/MPC563 Reference Manual, Rev. 1.2
NOTE
Operating Modes
14
15
16
17
7
8
9
10
11
12
13
14
15
16
17
Freescale Semiconductor