KIT EVALUATION FOR MPC565/566

MPC566EVB

Manufacturer Part Number
MPC566EVB
Description
KIT EVALUATION FOR MPC565/566
Manufacturer
Freescale Semiconductor
Datasheets

Specifications of MPC566EVB

Processor To Be Evaluated
MPC56x
Data Bus Width
32 bit
Interface Type
RS-232, Ethernet
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Freescale Semiconductor, Inc.
Commands
GO
Execute
Usage:
GO <addr>
The GO command executes target code starting at address addr. The value for addr may be an
absolute address specified as a hexadecimal value, or a symbol name.
If no argument is provided, the GO command begins executing instructions at the current program
counter.
When the GO command is executed, all user-defined breakpoints are inserted into the target code,
and the context is switched to the target program. Control is only regained when the target code
encounters a breakpoint, illegal instruction, or other exception which causes control to be handed
back to dBUG.
The GO command is repeatable.
Examples:
To execute code at the current program counter, the command is:
go
To execute code at the C function main(), the command is:
go _main
To execute code at the address 0x0004_0000, the command is:
go 40000