PM5S-A-24-240V Panasonic Electric Works, PM5S-A-24-240V Datasheet - Page 13

TIMER RELAY ANALOG 24-240V

PM5S-A-24-240V

Manufacturer Part Number
PM5S-A-24-240V
Description
TIMER RELAY ANALOG 24-240V
Manufacturer
Panasonic Electric Works
Series
PM5Sr
Type
Timerr
Datasheets

Specifications of PM5S-A-24-240V

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.1 Sec ~ 500 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
24 ~ 240VAC/DC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-2831

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PM5S-A-24-240V
Manufacturer:
Panasonic Electric Works
Quantity:
135
TIMERS SELECTOR CHART
Each model has various
time ranges. See the
product lists before
ordering.
operation)
(resistive)
accuracy
Life (Min.
Terminal layouts and wiring diagrams
Control
output
Time
Time range
Rated operating voltage
Model/Product Name
Available standards
Min. power off time
Mounting method
Operation mode
Mounting parts
Arrangement
Major uses
Operation time fluctuation
Features
Page
Temperature error
Voltage error
Current
Setting error
Mechanical
Electrical
Voltage
1000h
0.01s
100h
30m
10m
0.1s
30h
10h
30s
10s
5m
2m
1m
7A
5A
3A
1h
5s
1s
INST: Timed-out 1 Form C,
(power off time change at the range of 0.1s to 1h)
(at 20°C ambient temp. at the range of –10 to +50°C)
(at the operating voltage changes between 85 to 110%)
For time control for short
or long time
PM4S
Multi-range analog timer
An affordable new series
timers
Terminal block, cap
Pin type
T.D: Timed-out 2 Form C
instantaneous 1 Form C
4
T.D: Timed-out 2 Form C
INST: Timed-out 1 Form C,
* Selected by front switch
MODE
T.D.
100 to 120 V AC,
200 to 240 V AC,
1
Power ON-delay
instantaneous 1 Form C
UL/c-UL, CE
250 V AC
12 V DC
24 V DC
NO
3
100 ms
COM
NC
P. 13
±5%
±1%
±2%
±1%
(–)
5A
10
10
3
2
POWER
7
5
4
1
4
5
8
INST.
4 time
ranges
selectable
1
6
7
COM
(+)
NC
NO
Selected
by front
switch
3
For time control for short
or long time
PM4H-A
Multi-range analog timer
16 time ranges are selectable.
1s to 500h (Max. range) is
controlled.
8 operation modes available.
Terminal block, cap, panel
cover, rubber gasket, mounting
frame
Pin type
Screw terminal type
Differential ON/OFF-delay (1)(2)
(+)
48 to 125V DC, 24 V AC/DC,
Operating
Reset input
voltage
N.C. N.O.
Start input
UL/CSA, CE, LLOYD
100 to 240 V AC,
Signal OFF-delay
Stop input
Pulse ON-Flicker
Pulse One-cycle
Pulse ON-delay
Pulse One-shot
(other models)
(–)
6
1
Pulse Flicker
N.O.
(–)
250 V AC
Timed-out
2 Form C
Operating voltage
12 V DC
100 ms
7
2
2 × 10
±0.3%
±0.5%
P. 17
N.C.
±2%
±5%
5A
10
8
3
3
4
5
2
9
4
5
1 11
7
10
11
5
6
Stop
input
Reset
input
Start
input
7
10
8
9
N.C. N.O.
(+)
N.C.
N.O.
For time control for short
or long time
PM4H-S
Multi-range analog timer
16 time ranges are selectable.
1s to 500h (Max. range) is
controlled in one unit.
Terminal block, cap, panel
cover, rubber gasket, mounting
frame
Pin type
Screw terminal type
48 to 125V DC, 24 V AC/DC,
N.C. N.O.
UL/CSA, CE, LLOYD
N.O.
(+)
100 to 240 V AC,
Power ON-delay
Operating
(other models)
(–)
voltage
6
1
Timed-out
Operating voltage
250 V AC
2 Form C
N.C.
12 V DC
100 ms
2 × 10
7
2
±0.3%
±0.5%
3
2
P. 17
±2%
±5%
5A
10
4
8
3
1
(–)
5
9
4
5
8
CR oscillation counting timer
7
10
11
5
6
7
N.C.
(+)
N.C. N.O.
N.O.
500h
16 time
ranges
selectable
0.1s
PM4H-M
Multi-range analog timer
16 time ranges are selectable.
1s to 500h (Max. range) is
controlled in one unit.
5 operation modes (with
instantaneous contact)
available.
Terminal block, cap, panel
cover, rubber gasket, mounting
frame
Pin type
Screw terminal type
48 to 125V DC, 24 V AC/DC,
(with instantaneous contact)
Instantaneous 1 Form C
N.C. N.O.
For self holding circuit
UL/CSA, CE, LLOYD
Timed-out 1 Form C
(+)
N.O.
Power One-cycle
100 to 240 V AC,
Power ON-flicker
Power ON-delay
Power One-shot
Operating
(other models)
Power Flicker
(–)
voltage
6
1
Operating voltage
250 V AC
N.C.
12 V DC
100 ms
2 × 10
7
2
±0.3%
±0.5%
3
2
P. 17
±2%
±5%
5A
10
4
1
8
3
(–)
5
9
4
5
8
7
10
11
5
6
7
N.C.
(+)
N.C. N.O.
N.O.
PM4H-SD/SDM
Star-Delta timer
4 time ranges are selectable.
2s to 100s (Max. range) is
controlled in one unit.
5 time ranges selectable for
the
Terminal block, cap, panel
cover, rubber gasket, mounting
frame
Pin type
No instantaneous contact
Pin type
With instantaneous contact
Instantaneous: 1 Form A
side: Timed-out 1 Form A
side: Timed-out 1 Form A
For SD motor start-up
UL/CSA, CE, LLOYD
Operating voltage
-
100 to 240 V AC,
3
2
Operating voltage
(other models)
4
1
3
2
Star-Delta
250 V AC
switching times.
24 V AC
500 ms
4
2 × 10
1
±0.3%
±0.5%
5
P. 23
±2%
±5%
8
5A
10
6
5
7
8
5
6
7
7
100s
4 time
ranges
selectable
0.2s
For all uses of power
OFF-delay
PM4H-F8/-F8R/-F11R
OFF-delay timer
Multiple time ranges are
selectable.
Power-OFF delay of max. 10
min. is controlled.
Terminal block, cap, panel
cover, rubber gasket, mounting
frame
Pin type
Screw terminal type
12 V DC, 24 V DC, 24 V AC
N.O.
N.C. N.O.
UL/CSA, CE, LLOYD
Timed-out 2 Form C
Timed-out 1 Form C
(+)
N.C.
Power OFF-delay
100 to 120 V AC,
200 to 240 V AC,
Operating
(–)
10s
3 time ranges selectable
0.04s
(other models)
voltage
6
1
[F8R type]
Operating voltage
250 V AC
3
2
7
2
±0.3%
±0.5%
P. 25
±2%
±5%
4
1
3A
10
10
8
3
(–)
7
5
9
4
5
8
Reset input
10
11
5
6
7
10min
3 time
ranges
selectable
0.04min
(+)
N.C. N.O.
N.C.
N.O.
3

Related parts for PM5S-A-24-240V