Z8F012ASB020EG Zilog, Z8F012ASB020EG Datasheet - Page 201

no-image

Z8F012ASB020EG

Manufacturer Part Number
Z8F012ASB020EG
Description
IC ENCORE XP MCU FLASH 1K 8SOIC
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheet

Specifications of Z8F012ASB020EG

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Connectivity
IrDA, UART/USART
Peripherals
Brown-out Detect/Reset, LED, LVD, POR, PWM, Temp Sensor, WDT
Number Of I /o
6
Program Memory Size
1KB (1K x 8)
Program Memory Type
FLASH
Eeprom Size
16 x 8
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
8-SOIC (3.9mm Width)
Processor Series
Z8F012Ax
Core
eZ8
Data Bus Width
8 bit
Data Ram Size
256 B
Interface Type
UART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
6
Number Of Timers
2
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Development Tools By Supplier
Z8F04A08100KITG, Z8F04A28100KITG, ZENETSC0100ZACG, ZENETSC0100ZACG, ZUSBOPTSC01ZACG, ZUSBSC00100ZAC, ZUSBSC00100ZACG
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 4 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
269-4038
Z8F012ASB020EG
Table 109. Oscillator Control Register (OSCCTL)
Oscillator Control Register Definitions
BITS
FIELD
RESET
R/W
ADDR
PS022825-0908
Caution:
Oscillator Control Register
INTEN
R/W
1
7
The Oscillator Control Register (OSCCTL) enables/disables the various oscillator circuits,
enables/disables the failure detection/recovery circuitry and selects the primary oscillator,
which becomes the system clock.
The Oscillator Control Register must be unlocked before writing. Writing the two step
sequence
is locked at successful completion of a register write to the OSCCTL.
INTEN—Internal Precision Oscillator Enable
1 = Internal precision oscillator is enabled
0 = Internal precision oscillator is disabled
XTLEN—Crystal Oscillator Enable; this setting overrides the GPIO register control for
PA0 and PA1
1 = Crystal oscillator is enabled
0 = Crystal oscillator is disabled
WDTEN—Watchdog Timer Oscillator Enable
1 = Watchdog Timer oscillator is enabled
0 = Watchdog Timer oscillator is disabled
SOFEN—System Clock Oscillator Failure Detection Enable
1 = Failure detection and recovery of system clock oscillator is enabled
0 = Failure detection and recovery of system clock oscillator is disabled
It is possible to disable the clock failure detection circuitry as well as all functioning
clock sources. In this case, the Z8 Encore! XP F082A Series device ceases
functioning and can only be recovered by Power-On-Reset.
XTLEN
E7H
R/W
6
0
followed by
WDTEN
R/W
5
1
18H
to the Oscillator Control Register unlocks it. The register
SOFEN
R/W
0
4
F86H
WDFEN
R/W
3
0
Z8 Encore! XP
R/W
0
2
Product Specification
SCKSEL
R/W
1
0
®
F082A Series
Oscillator Control
R/W
0
0
190

Related parts for Z8F012ASB020EG