HD64F2623FA20J Renesas Electronics America, HD64F2623FA20J Datasheet - Page 462

IC H8S MCU FLASH 256K 100-QFP

HD64F2623FA20J

Manufacturer Part Number
HD64F2623FA20J
Description
IC H8S MCU FLASH 256K 100-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheets

Specifications of HD64F2623FA20J

Core Processor
H8S/2600
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
53
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
12K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2623FA20J
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F2623FA20J
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64F2623FA20J
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD64F2623FA20JV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 13 Serial Communication Interface (SCI)
Bit 6—Receive Data Register Full (RDRF): Indicates that the received data is stored in RDR.
Bit 6
RDRF
0
1
Note: RDR and the RDRF flag are not affected and retain their previous values when an error is
Bit 5—Overrun Error (ORER): Indicates that an overrun error occurred during reception,
causing abnormal termination.
Bit 5
ORER
0
1
Notes: 1. The ORER flag is not affected and retains its previous state when the RE bit in SCR is
Rev. 5.00 Jan 10, 2006 page 436 of 1042
REJ09B0275-0500
detected during reception or when the RE bit in SCR is cleared to 0.
If reception of the next data is completed while the RDRF flag is still set to 1, an overrun
error will occur and the receive data will be lost.
2. The receive data prior to the overrun error is retained in RDR, and the data received
cleared to 0.
subsequently is lost. Also, subsequent serial reception cannot be continued while the
ORER flag is set to 1. In clocked synchronous mode, serial transmission cannot be
continued, either.
Description
[Clearing conditions]
[Setting condition]
When serial reception ends normally and receive data is transferred from RSR to RDR
Description
[Clearing condition]
When 0 is written to ORER after reading ORER = 1
[Setting condition]
When the next serial reception is completed while RDRF = 1 *
When 0 is written to RDRF after reading RDRF = 1
When the DTC is activated by an RXI interrupt and reads data from RDR
2
(Initial value) *
(Initial value)
1

Related parts for HD64F2623FA20J