AD9517-4BCPZ Analog Devices Inc, AD9517-4BCPZ Datasheet - Page 31

IC CLOCK GEN 1.8GHZ VCO 48-LFCSP

AD9517-4BCPZ

Manufacturer Part Number
AD9517-4BCPZ
Description
IC CLOCK GEN 1.8GHZ VCO 48-LFCSP
Manufacturer
Analog Devices Inc
Type
Clock Generator, Fanout Distributionr
Datasheet

Specifications of AD9517-4BCPZ

Design Resources
High Performance, Dual Channel IF Sampling Receiver (CN0140)
Pll
Yes
Input
CMOS, LVDS, LVPECL
Output
CMOS, LVDS, LVPECL
Number Of Circuits
1
Ratio - Input:output
1:12
Differential - Input:output
Yes/Yes
Frequency - Max
1.8GHz
Divider/multiplier
Yes/No
Voltage - Supply
3.135 V ~ 3.465 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-LFCSP
Frequency-max
1.8GHz
Clock Ic Type
Clock Generator
Ic Interface Type
Serial
Frequency
1.8GHz
No. Of Outputs
12
Supply Current
100µA
Supply Voltage Range
3.135V To 3.465V
Digital Ic Case Style
LFCSP
Rohs Compliant
Yes
For Use With
AD9517-4/PCBZ - BOARD EVALUATION AD9517-4
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Clock Distribution or External VCO < 1600 MHz
When the external clock source to be distributed or the external
VCO/VCXO is <1600 MHz, a configuration that bypasses the
VCO divider can be used. This differs from the High Frequency
Clock Distribution—CLK or External VCO > 1600 MHz
section only in that the VCO divider (divide-by-2, divide-by-3,
divide-by-4, divide-by-5, and divide-by-6) is bypassed. This
limits the frequency of the clock source to <1600 MHz (due to the
maximum input frequency allowed at the channel dividers).
Configuration and Register Settings
For clock distribution applications where the external clock is
<1600 MHz, the register settings shown in Table 25 should be
used.
Table 25. Settings for Clock Distribution < 1600 MHz
Register
0x010[1:0] = 01b
0x1E1[0] = 1b
0x1E1[1] = 0b
Function
PLL asynchronous power-down (PLL off )
Bypass the VCO divider as source for
distribution section
CLK selected as the source
Rev. B | Page 31 of 80
When using the internal PLL with an external VCO < 1600 MHz,
the PLL must be turned on.
Table 26. Settings for Using Internal PLL with External VCO <
1600 MHz
Register
0x1E1[0] = 1b
0x010[1:0] = 00b
An external VCO/VCXO requires an external loop filter that
must be connected between CP and the tuning pin of the
VCO/VCXO. This loop filter determines the loop bandwidth
and stability of the PLL. Make sure to select the proper PFD
polarity for the VCO/VCXO being used.
Table 27. Setting the PFD Polarity
Register
0x010[7] = 0b
0x010[7] = 1b
After the appropriate register values are programmed,
Register 0x232 must be set to 0x01 for the values to take effect.
PFD polarity positive (higher control voltage
PFD polarity negative (higher control
Function
produces higher frequency)
voltage produces lower frequency)
Function
Bypass the VCO divider as source for
distribution section
PLL normal operation (PLL on) along with
other appropriate PLL settings in 0x10 to
0x1E
AD9517-4