Z84C3006PEG Zilog, Z84C3006PEG Datasheet - Page 98

IC 6MHZ Z80 CMOS CTC 28-PDIP

Z84C3006PEG

Manufacturer Part Number
Z84C3006PEG
Description
IC 6MHZ Z80 CMOS CTC 28-PDIP
Manufacturer
Zilog
Type
Counter/Timer Circuit (CTC)r
Series
Z80r
Datasheets

Specifications of Z84C3006PEG

Frequency
6MHz
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
8mA
Operating Temperature
-40°C ~ 100°C
Package / Case
28-DIP (0.600", 15.24mm)
Processor Series
Z84C3xx
Core
Z80
Data Bus Width
8 bit
Maximum Clock Frequency
6 MHz
Operating Supply Voltage
0 V to 5 V
Maximum Operating Temperature
+ 100 C
Mounting Style
Through Hole
Minimum Operating Temperature
- 40 C
Filter Terminals
SMD
Ic Generic Number
84C30
Operating Temperature Min
-40°C
Operating Temperature Max
100°C
Clock Frequency
6MHz
Rohs Compliant
Yes
Cpu Speed
6MHz
Digital Ic Case Style
DIP
No. Of Pins
28
Supply Voltage Range
5V
Operating Temperature Range
-40°C To +100°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Count
-
Lead Free Status / Rohs Status
 Details
Other names
269-3910
Z84C3006PEG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z84C3006PEG
Manufacturer:
ZILOG
Quantity:
1 980
Part Number:
Z84C3006PEG
Manufacturer:
Zilog
Quantity:
1 722
Part Number:
Z84C3006PEG
Manufacturer:
ZILOG
Quantity:
1 980
Part Number:
Z84C3006PEG
Manufacturer:
WSI
Quantity:
4 970
Part Number:
Z84C3006PEG
Manufacturer:
ZILOG
Quantity:
20 000
78
UM008005-0205
Z80 CPU
User’s Manual
(
condition is determined by examining the sign bits of the operands.
For addition, operands with different signs never cause Overflow. When
adding operands with like signs and the result has a different sign, the
Overflow Flag is set, for example:
The two numbers added together resulted in a number that exceeds
and the two positive operands have resulted in a negative number (-
which is incorrect. The Overflow Flag is therefore set.
For subtraction, Overflow can occur for operands of unlike signs. Operands
of like signs never cause Overflow. For example:
The minuend sign has changed from a Positive to a negative, giving an
incorrect difference. Overflow is set.
Another method for identifying an Overflow is to observe the Carry to and
out of the sign bit. If there is a Carry in and no Carry out, or if there is no
Carry in and a Carry out, then Overflow has occurred.
This flag is also used with logical operations and rotate instructions to
indicate the resulting parity is Even. The number of
counted. If the total is Odd, ODD parity is flagged (P =
Even, EVEN parity is flagged (P =
During search instructions (
instructions (
+120
+105
+225
(-)
+127
+127
+191
) or is less than the minimum possible number (–
-64
=
=
=
LDI
0111
1100
1011
0111
0110
1110
,
LDIR
1000
1001
0001
,
1111
0000
1111
LDD
CPI
,
LDDR
,
ADDEND
AUGEND
(-95)
MINUEND
SUBTRAHEND
DIFFERENCE
CPIR
1
), the P/V Flag monitors the state of the
).
,
CPD
,
CPDR
SUM
) and block transfer
1
bits in a byte are
128
0
Z80 Instruction Set
). If the total is
). This Overflow
+127
95
),

Related parts for Z84C3006PEG