Specifications of EP1S20F780I6N

Number Of Logic Elements/cells
18460
Number Of Labs/clbs
1846
Total Ram Bits
1669248
Number Of I /o
586
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
780-FBGA
Family Name
Stratix
Number Of Logic Blocks/elements
18460
# I/os (max)
586
Frequency (max)
450.05MHz
Process Technology
0.13um (CMOS)
Operating Supply Voltage (typ)
1.5V
Logic Cells
18460
Ram Bits
1669248
Operating Supply Voltage (min)
1.425V
Operating Supply Voltage (max)
1.575V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
780
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1S20F780I6N
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP1S20F780I6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S20F780I6N
Manufacturer:
ALTERA
0
Software Support
Figure 5–42. Page 3 of the Transmitter altlvds MegaWizard Plug-In Manager
5–66
Stratix Device Handbook, Volume 2
Number of Channels
The What is the number of channels? parameter specifies the number of
transmitter channels required and the width of the tx_in port. You can
have more than 20 channels in a transmitter or receiver module by typing
in the required number instead of choosing a number from the drop
down menu, which only has selections of up to 20 channels.
Deserialization Factor
The What is the deserialization factor? parameter specifies the number
of bits per channel. The transmitter block supports deserialization factors
of 4, 7, 8, and 10. Based on the factor specified, the Quartus II software
determines the multiplication and/or division factor for the LVDS PLL in
order to serialize the data.
Table 5–5 on page 5–32
parallel data for the n
[(J
×
n) – 1]) to the LSB (rx_out bit [J
th
lists the differential bit naming convention. The
channel spans from the MSB (rx_out bit
×
(n – 1)]), where J is the
Altera Corporation
July 2005

Related parts for EP1S20F780I6N