EP20K400EFC672-1X Altera, EP20K400EFC672-1X Datasheet - Page 49

IC APEX 20KE FPGA 400K 672-FBGA

EP20K400EFC672-1X

Manufacturer Part Number
EP20K400EFC672-1X
Description
IC APEX 20KE FPGA 400K 672-FBGA
Manufacturer
Altera
Series
APEX-20K®r
Datasheet

Specifications of EP20K400EFC672-1X

Number Of Logic Elements/cells
16640
Number Of Labs/clbs
1664
Total Ram Bits
212992
Number Of I /o
488
Number Of Gates
1052000
Voltage - Supply
1.71 V ~ 1.89 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
672-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
544-1102

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP20K400EFC672-1X
Manufacturer:
ALTERA
Quantity:
2
Part Number:
EP20K400EFC672-1X
Manufacturer:
ALTERA
Quantity:
3
Part Number:
EP20K400EFC672-1X
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP20K400EFC672-1X
Manufacturer:
ALTERA
Quantity:
1
Part Number:
EP20K400EFC672-1X
Manufacturer:
ALTERA
0
Part Number:
EP20K400EFC672-1X
Manufacturer:
ALTERA
Quantity:
120
Part Number:
EP20K400EFC672-1X
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP20K400EFC672-1XN
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP20K400EFC672-1XN
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP20K400EFC672-1XN
Manufacturer:
ALTERA
0
Altera Corporation
Clock Phase & Delay Adjustment
The APEX 20KE ClockShift feature allows the clock phase and delay to be
adjusted. The clock phase can be adjusted by 90° steps. The clock delay
can be adjusted to increase or decrease the clock delay by an arbitrary
amount, up to one clock period.
LVDS Support
Two PLLs are designed to support the LVDS interface. When using LVDS,
the I/O clock runs at a slower rate than the data transfer rate. Thus, PLLs
are used to multiply the I/O clock internally to capture the LVDS data. For
example, an I/O clock may run at 105 MHz to support 840 megabits per
second (Mbps) LVDS data transfer. In this example, the PLL multiplies the
incoming clock by eight to support the high-speed data transfer. You can
use PLLs in EP20K400E and larger devices for high-speed LVDS
interfacing.
Lock Signals
The APEX 20KE ClockLock circuitry supports individual LOCK signals.
The LOCK signal drives high when the ClockLock circuit has locked onto
the input clock. The LOCK signals are optional for each ClockLock circuit;
when not used, they are I/O pins.
ClockLock & ClockBoost Timing Parameters
For the ClockLock and ClockBoost circuitry to function properly, the
incoming clock must meet certain requirements. If these specifications are
not met, the circuitry may not lock onto the incoming clock, which
generates an erroneous clock within the device. The clock generated by
the ClockLock and ClockBoost circuitry must also meet certain
specifications. If the incoming clock meets these requirements during
configuration, the APEX 20K ClockLock and ClockBoost circuitry will
lock onto the clock during configuration. The circuit will be ready for use
immediately after configuration. In APEX 20KE devices, the clock input
standard is programmable, so the PLL cannot respond to the clock until
the device is configured. The PLL locks onto the input clock as soon as
configuration is complete.
clock specifications.
1
For more information on ClockLock and ClockBoost circuitry,
see Application Note 115: Using the ClockLock and ClockBoost PLL
Features in APEX Devices.
APEX 20K Programmable Logic Device Family Data Sheet
Figure 30
shows the incoming and generated
49