DS3172+ Maxim Integrated Products, DS3172+ Datasheet - Page 145

IC TXRX DS3/E3 DUAL 400-BGA

DS3172+

Manufacturer Part Number
DS3172+
Description
IC TXRX DS3/E3 DUAL 400-BGA
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS3172+

Function
Single-Chip Transceiver
Interface
DS3, E3
Number Of Circuits
2
Voltage - Supply
3.135 V ~ 3.465 V
Current - Supply
328mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
400-BGA
Includes
DS3 Framers, E3 Framers, HDLC Controller, On-Chip BERTs
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
DS3171/DS3172/DS3173/DS3174
Bit 5: Receive New Pattern Load (RNPL) – A zero to one transition of this bit will cause the programmed test
pattern (QRSS, PTS, PLF[4:0}, PTF[4:0], and BSP[31:0]) to be loaded in to the receive pattern generator. This bit
must be changed to zero and back to one for another pattern to be loaded. Loading a new pattern will forces the
receive pattern generator out of the “Sync” state which causes a resynchronization to be initiated.
Note: QRSS, PTS, PLF[4:0}, PTF[4:0], and BSP[31:0] must not change from the time this bit transitions from 0 to 1
until four receive clock cycles after this bit transitions from 0 to 1. Register bit PORT.CR1.BENA must be set and
the receive clock running in order for the pattern load to take affect.
Bit 4: Receive Pattern Inversion Control (RPIC) – When 0, the receive incoming data stream is not altered.
When 1, the receive incoming data stream is inverted.
Bit 3: Manual Pattern Resynchronization (MPR) – A zero to one transition of this bit will cause the receive
pattern generator to resynchronize to the incoming pattern. This bit must be changed to zero and back to one for
another resynchronization to be initiated. Note: A manual resynchronization forces the receive pattern generator
out of the “Sync” state.
Bit 2: Automatic Pattern Resynchronization Disable (APRD) – When 0, the receive pattern generator will
automatically resynchronize to the incoming pattern if six or more times during the current 64-bit window the
incoming data stream bit and the receive pattern generator output bit did not match. When 1, the receive pattern
generator will not automatically resynchronize to the incoming pattern.
Bit 1: Transmit New Pattern Load (TNPL) – A zero to one transition of this bit will cause the programmed test
pattern (QRSS, PTS, PLF[4:0}, PTF[4:0], and BSP[31:0]) to be loaded in to the transmit pattern generator. This bit
must be changed to zero and back to one for another pattern to be loaded.
Note: QRSS, PTS, PLF[4:0}, PTF[4:0], and BSP[31:0] must not change from the time this bit transitions from 0 to 1
until four transmit clock cycles after this bit transitions from 0 to 1. Register bit PORT.CR1.BENA must be set and
the receive clock running in order for the pattern load to take affect.
Bit 0: Transmit Pattern Inversion Control (TPIC) – When 0, the transmit outgoing data stream is not altered.
When 1, the transmit outgoing data stream is inverted.
145