AD9776A Analog Devices, AD9776A Datasheet - Page 32

no-image

AD9776A

Manufacturer Part Number
AD9776A
Description
Dual 12-Bit, 1 GSPS, Digital-to-Analog Converter
Manufacturer
Analog Devices
Datasheet

Specifications of AD9776A

Resolution (bits)
12bit
Dac Update Rate
1GSPS
Dac Settling Time
n/a
Max Pos Supply (v)
+3.47V
Single-supply
No
Dac Type
Current Out
Dac Input Format
Par

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9776ABSVZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD9776ABSVZRL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
AD9776A/AD9778A/AD9779A
Register Name
AUX DAC2 Control
Interrupt
Version
Register
Address
0x12
0x11
0x12
0x12
0x12
0x13 to
0x18
0x19
0x19
0x19
0x19
0x19
0x19
0x1F
Bits
1:0
7:0
7
6
5
7
6
4
3
2
0
7:0
Parameter
Auxiliary DAC2 Data[9:8]
Auxiliary DAC2 Data[7:0]
Auxiliary DAC2 sign
Auxiliary DAC2 current
direction
Auxiliary DAC2 power-down
Reserved
Data timing error IRQ
Sync timing error IRQ
Data timing error type
Data timing error IRQ enable
Sync timing error IRQ enable
Internal sync loopback
Version[7:0]
Rev. B | Page 32 of 56
Function
Auxiliary DAC2 Data[9:0] is the 10-bit output
current control word. Magnitude of the auxiliary
DAC current increases with increasing value. Bit 9 is
the MSB and Bit 0 is the LSB.
1: AUX2_N active.
0: source.
1: sink.
1: auxiliary DAC2 off.
Read only. Active high indicates a timing violation
occurred on the input data port. The IRQ is latched.
This bit is cleared when the Interrupt register is read.
Read only. Active high indicates a timing violation
occurred on the SYNC_I input. The IRQ is latched.
This bit is cleared when the Interrupt register is read.
Read only. Indicates the timing error type.
0: hold time violation.
1: setup time violation.
Meaningful when data timing error IRQ is active.
1: data timing error IRQ is enabled.
1: sync timing error IRQ is enabled.
The received SYNC_O signal is looped back to the
SYNC_I signal.
Indicates device hardware revision number.
0: AUX2_P active.
0: auxiliary DAC2 on.
0: data timing error IRQ is masked.
0: sync timing error IRQ is masked.
Default
00
00000000
0
0
0
0
0
0
0
0
0
00000111