Datasheet

Specifications of TMPM363F10FG

Product Summaries
Summary
Lead Free
Yes
Rohs Compatible Product(s)
Available
Rom (kbytes)
1024K
Rom Type
Flash
Ram (kbytes)
64K
Number Of Pins
100
Package
LQFP(14x14)
Vcc
3V
Cpu Mhz
64
Ssp (ch) Spi
1
I2c/sio (ch)
4
Uart/sio (ch)
5
Usb
Host
Can
1
Ethernet
-
External Bus Interface
Y
Cs/wait Controller (ch)
4
Dma Controller
2
10-bit Da Converter
8
10-bit Ad Converter
8
12-bit Ad Converter
-
16-bit Timer / Counter
16
Motor / Igbt Control
-
Real Time Clock
Y
Watchdog Timer
Y
Osc Freq Detect
-
Clock Gear
Y
Low-power Hold Function
Y
Remote Control Interface
Y
Hardware Cec Controller
Y
Comparators
-
Low-voltage Detector
-
Etm Hardware Trace
4-bit

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMPM363F10FG
Manufacturer:
Toshiba
Quantity:
10 000
22.4
Description of Operations
22.4
22.4.1
22.4.2
22.4.2.1
Description of Operations
be applied to the VREFL pin.
which time the internal reference voltage should stabilize, and then write "1" to the ADMOD0<ADS> bit.
to a switched -off state. To switch to the power-consumption mode, set "0" to the <VREFON> bit after conver-
sion.
The "High" level of the analog reference voltage shall be applied to the VRFEH pin, and the "Low" shall
To start AD conversion, make sure that you first write "1" to the <VREFON> bit, wait for 3 μs during
By writing "0" to the ADMOD1<VREFON> bit, a switched-on state of VREFH - VREFL can be turned in-
Two types of AD conversion are supported: normal AD conversion and top-priority AD conversion.
For normal AD conversion, the following four operation modes are supported.
is selected with the ADMOD0<REPEAT, SCAN>.
Analog Reference Voltage
AD Conversion Mode
Note:VREFL and AVSS are shared by TMPM363F10FG.
(1)
(2)
For normal AD conversion, the following four operation modes are supported and the operation mode
Normal AD conversion
nel single conversion mode.
completed, ADMOD0<EOCFN> is set to "1", ADMOD0<ADBFN> is cleared to "0", and the AD con-
version completion interrupt request (INTAD) is generated. <EOCFN> is cleared to "0" upon read.
single conversion mode.
version is completed, ADMOD0<EOCFN> is set to "1", ADMOD0<ADBFN> is cleared to "0",
and the conversion completion interrupt request (INTAD) is generated. <EOCFN> is cleared to "0".
・ Fixed channel single conversion mode
・ Channel scan single conversion mode
・ Fixed channel repeat conversion mode
・ Channel scan repeat conversion mode
If ADMOD0<REPEAT, SCAN> is set to "00", "AD conversion is performed in the fixed chan-
In this mode, AD conversion is performed once for one channel selected. After AD conversion is
If ADMOD0<REPEAT, SCAN> is set to "01", "AD conversion is performed in the channel scan
In this mode, AD conversion is performed once for each scan channel selected. After AD scan con-
Fixed channel single conversion mode
Channel scan single conversion mode