m41t81 STMicroelectronics, m41t81 Datasheet - Page 13

no-image

m41t81

Manufacturer Part Number
m41t81
Description
Serial Access Real-time Clock With Alarms
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M41T81
Manufacturer:
ST
0
Part Number:
M41T81
Manufacturer:
ST
Quantity:
4 840
Part Number:
m41t81 RTC
Manufacturer:
ST
0
Part Number:
m41t81(MT41T81)
Manufacturer:
ST
0
Part Number:
m41t813
Manufacturer:
ST
0
Part Number:
m41t815MY6
Manufacturer:
ST
0
Part Number:
m41t81M6E
Manufacturer:
ST
Quantity:
2 028
Part Number:
m41t81M6E
Manufacturer:
ST
Quantity:
20 000
Part Number:
m41t81M6F
Manufacturer:
STM
Quantity:
1 364
Part Number:
m41t81M6F
Manufacturer:
ST
Quantity:
310
Part Number:
m41t81M6F
Manufacturer:
ST
Quantity:
20 000
Part Number:
m41t81M6F
Manufacturer:
ST
Quantity:
13 135
Part Number:
m41t81M6F
Manufacturer:
ST
Quantity:
18 504
Company:
Part Number:
m41t81M6F
Quantity:
20 000
M41T81
3
Note:
3.1
3.2
Clock operation
The 20-byte Register Map (see
the date and time from the clock, in a binary coded decimal format. Tenths/Hundredths of
Seconds, Seconds, Minutes, and Hours are contained within the first four registers.
The Tenths/Hundredths of Seconds cannot be written to any value other than “00.”
Bits D6 and D7 of Clock Register 03h (Century/Hours Register) contain the CENTURY
ENABLE Bit (CEB) and the CENTURY Bit (CB). Setting CEB to a '1' will cause CB to toggle,
either from '0' to '1' or from '1' to '0' at the turn of the century (depending upon its initial
state). If CEB is set to a '0,' CB will not toggle. Bits D0 through D2 of Register 04h contain
the Day (day of week). Registers 05h, 06h, and 07h contain the Date (day of month), Month
and Years. The ninth clock register is the Control Register (this is described in the Clock
Calibration section). Bit D7 of Register 01h contains the STOP Bit (ST). Setting this bit to a
'1' will cause the oscillator to stop. If the device is expected to spend a significant amount of
time on the shelf, the oscillator may be stopped to reduce current drain. When reset to a '0'
the oscillator restarts within one second.
The eight Clock Registers may be read one byte at a time, or in a sequential block. Provision
has been made to assure that a clock update does not occur while any of the eight clock
addresses are being read. If a clock address is being read, an update of the clock registers
will be halted. This will prevent a transition of data during the READ.
Power-down time-stamp
When a power failure occurs, the HT Bit will automatically be set to a '1.' This will prevent the
clock from updating the TIMEKEEPER
time of the power-down event. Resetting the HT Bit to a '0' will allow the clock to update the
TIMEKEEPER registers with the current time. For more information, see Application Note
AN1572.
Clock registers
The M41T81 offers 20 internal registers which contain Clock, Alarm, Watchdog, Flag,
Square Wave and Control data. These registers are memory locations which contain
external (user accessible) and internal copies of the data (usually referred to as BiPORT
cells). The external copies are independent of internal functions except that they are
updated periodically by the simultaneous transfer of the incremented internal copy. The
internal divider (or clock) chain will be reset upon the completion of a WRITE to any clock
address.
The system-to-user transfer of clock data will be halted whenever the address being read is
a clock address (00h to 07h). The update will resume either due to a Stop Condition or when
the pointer increments to any non-clock address (08h-13h).
Clock and Alarm Registers store data in BCD. Control, Watchdog and Square Wave
Registers store data in Binary Format.
Table 2 on page
®
registers, and will allow the user to read the exact
14) is used to both set the clock and to read
Clock operation
13/30

Related parts for m41t81