m41t81 STMicroelectronics, m41t81 Datasheet - Page 17

no-image

m41t81

Manufacturer Part Number
m41t81
Description
Serial Access Real-time Clock With Alarms
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M41T81
Manufacturer:
ST
0
Part Number:
M41T81
Manufacturer:
ST
Quantity:
4 840
Part Number:
m41t81 RTC
Manufacturer:
ST
0
Part Number:
m41t81(MT41T81)
Manufacturer:
ST
0
Part Number:
m41t813
Manufacturer:
ST
0
Part Number:
m41t815MY6
Manufacturer:
ST
0
Part Number:
m41t81M6E
Manufacturer:
ST
Quantity:
2 028
Part Number:
m41t81M6E
Manufacturer:
ST
Quantity:
20 000
Part Number:
m41t81M6F
Manufacturer:
STM
Quantity:
1 364
Part Number:
m41t81M6F
Manufacturer:
ST
Quantity:
310
Part Number:
m41t81M6F
Manufacturer:
ST
Quantity:
20 000
Part Number:
m41t81M6F
Manufacturer:
ST
Quantity:
13 135
Part Number:
m41t81M6F
Manufacturer:
ST
Quantity:
18 504
Company:
Part Number:
m41t81M6F
Quantity:
20 000
M41T81
3.4
Note:
Setting alarm clock registers
Address locations 0Ah-0Eh contain the alarm settings. The alarm can be configured to go
off at a prescribed time on a specific month, date, hour, minute, or second or repeat every
year, month, day, hour, minute, or second. It can also be programmed to go off while the
M41T81 is in the battery back-up mode to serve as a system wake-up call.
Bits RPT5-RPT1 put the alarm in the repeat mode of operation.
the possible configurations. Codes not listed in the table default to the once per second
mode to quickly alert the user of an incorrect alarm setting.
When the clock information matches the alarm clock settings based on the match criteria
defined by RPT5-RPT1, the AF (Alarm Flag) is set. If AFE (Alarm Flag Enable) is also set
(and SQWE is '0.'), the alarm condition activates the IRQ/FT/OUT/SQW pin.
If the address pointer is allowed to increment to the Flag Register address, an alarm
condition will not cause the Interrupt/Flag to occur until the address pointer is moved to a
different address. It should also be noted that if the last address written is the “Alarm
Seconds,” the address pointer will increment to the Flag address, causing this situation to
occur.
The IRQ/FT/OUT/SQW output is cleared by a READ to the Flags Register as shown in
Figure
the Alarm Flag has been reset to '0.'
The IRQ/FT/OUT/SQW pin can also be activated in the battery back-up mode. The
IRQ/FT/OUT/SQW will go low if an alarm occurs and both ABE (Alarm in Battery Back-up
Mode Enable) and AFE are set.
Figure 12. Alarm interrupt reset waveform
IRQ/FT/OUT/SQW
ACTIVE FLAG
12. A subsequent READ of the Flags Register is necessary to see that the value of
0Eh
Figure 13
illustrates the back-up mode alarm timing.
0Fh
Table 3 on page 18
Clock operation
HIGH-Z
10h
shows
AI04617
17/30