ep1sgx25d Altera Corporation, ep1sgx25d Datasheet - Page 25

no-image

ep1sgx25d

Manufacturer Part Number
ep1sgx25d
Description
Stratix Gx Device Family Data Sheet
Manufacturer
Altera Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ep1sgx25dF1020
Manufacturer:
ALTERA
0
Part Number:
ep1sgx25dF1020C5
Manufacturer:
Altera
Quantity:
10 000
Part Number:
ep1sgx25dF1020C5
Manufacturer:
ALTERA
0
Part Number:
ep1sgx25dF1020C5
Manufacturer:
ALTERA
Quantity:
200
Part Number:
ep1sgx25dF1020C5N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
ep1sgx25dF1020C5N
Manufacturer:
ALTERA
0
Part Number:
ep1sgx25dF1020C6
Manufacturer:
ALTERA
Quantity:
7
Part Number:
ep1sgx25dF1020C6
Manufacturer:
ALTERA
Quantity:
1 045
Part Number:
ep1sgx25dF1020C6
Manufacturer:
ALTERA
Quantity:
200
Part Number:
ep1sgx25dF1020C6N
Manufacturer:
ALTERA
Quantity:
3 000
Altera Corporation
June 2006
Figure 2–12. External Termination & Biasing Circuit
Programmable Equalizer
The programmable equalizer module boosts the high frequency
components of the incoming signal to compensate for losses in the
transmission medium. There are five possible equalization settings (0, 1,
2, 3, 4) to compensate for 0”, 10”, 20”, 30”, and 40” of FR4 trace. These
settings should be interpreted loosely. The programmable equalizer can
be set dynamically or statically.
Receiver PLL & CRU
Each transceiver block has four receiver PLLs and CRUs, each of which is
dedicated to a receive channel. If the receive channel associated with a
particular receiver PLL or CRU is not used, then the receiver PLL or CRU
is powered down for the channel.
PLL and CRU circuits.
50/60/75- Ω
Termination
Resistance
Transmission
Line
Receiver External Termination
and Biasing
V
DD
Receiver External Termination
× {R2/(R1 + R 2)} = 1.1 V
R1/R2 = 1K
V
C1
and Biasing
DD
Figure 2–13
Stratix GX Device Handbook, Volume 1
R2
is a diagram of the receiver
R1
Stratix GX Transceivers
Stratix GX Device
RXIN
RXIP
Receiver
2–15

Related parts for ep1sgx25d