at85c51snd3b ATMEL Corporation, at85c51snd3b Datasheet - Page 65

no-image

at85c51snd3b

Manufacturer Part Number
at85c51snd3b
Description
Single-chip Digital Audio Decoder - Encoder With Usb 2.0 Interface
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
at85c51snd3b1-7FTUL
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at85c51snd3b1-RTTUL
Manufacturer:
Atmel
Quantity:
10 000
Timers/Counters
Timer/Counter
Operations
Timer Clock Controller
7632C–MP3–11/06
The AT85C51SND3B derivatives implement 2 general-purpose, 16-bit Timers/Counters.
They are identified as Timer 0 and Timer 1, and can be independently configured to
operate in a variety of modes as a Timer or as an event Counter. When operating as a
Timer, the Timer/Counter runs for a programmed length of time, then issues an interrupt
request. When operating as a Counter, the Timer/Counter counts negative transitions
on an external pin. After a preset number of counts, the Counter issues an interrupt
request.
The various operating modes of each Timer/Counter are described in the following
sections.
For instance, a basic operation is Timer registers THx and TLx (x = 0, 1) connected in
cascade to form a 16-bit Timer. Setting the run control bit (TRx) in TCON register (see
Table 81) turns the Timer on by allowing the selected input to increment TLx. When TLx
overflows it increments THx; when THx overflows it sets the Timer overflow flag (TFx) in
TCON register. Setting the TRx does not clear the THx and TLx Timer registers. Timer
registers can be accessed to obtain the current count or to enter preset values. They
can be read at any time but TRx bit must be cleared to preset their values, otherwise,
the behavior of the Timer/Counter is unpredictable.
The C/Tx# control bit selects Timer operation or Counter operation by selecting the
divided-down peripheral clock or external pin Tx as the source for the counted signal.
TRx bit must be cleared when changing the mode of operation, otherwise the behavior
of the Timer/Counter is unpredictable.
For Timer operation (C/Tx# = 0), the Timer register counts the divided-down peripheral
clock. The Timer register is incremented once every peripheral cycle (6 peripheral clock
periods). The Timer clock rate is F
mode.
For Counter operation (C/Tx# = 1), the Timer register counts the negative transitions on
the Tx external input pin. The external input is sampled every peripheral cycles. When
the sample is high in one cycle and low in the next one, the Counter is incremented.
Since it takes 2 cycles (12 peripheral clock periods) to recognize a negative transition,
the maximum count rate is F
mode. There are no restrictions on the duty cycle of the external input signal, but to
ensure that a given level is sampled at least once before it changes, it should be held for
at least one full peripheral cycle.
As shown in Figure 31, the Timer 0 (FT0) and Timer 1 (FT1) clocks are derived from
either the peripheral clock (F
and T1X2 bits in CKCON register. These clocks are issued from the Clock Controller
block as detailed in Section “Oscillator”, page 28. When T0X2 or T1X2 bit is set, the
Timer 0 or Timer 1 clock frequency is fixed and equal to the oscillator clock frequency
divided by 2. When cleared, the Timer clock frequency is equal to the oscillator clock fre-
quency divided by 2 in standard mode or to the oscillator clock frequency in X2 mode.
PER
PER
) or the oscillator clock (F
/12, i.e., F
PER
/6, i.e., F
OSC
OSC
/24 in standard mode or F
/12 in standard mode or F
AT85C51SND3B
OSC
) depending on the T0X2
OSC
OSC
/12 in X2
/6 in X2
65

Related parts for at85c51snd3b