STEVAL-IHM015V1 STMicroelectronics, STEVAL-IHM015V1 Datasheet - Page 39

BOARD EVAL ST7FMC2S4T6/STS8DNH3L

STEVAL-IHM015V1

Manufacturer Part Number
STEVAL-IHM015V1
Description
BOARD EVAL ST7FMC2S4T6/STS8DNH3L
Manufacturer
STMicroelectronics
Type
Motor / Motion Controllers & Driversr
Datasheets

Specifications of STEVAL-IHM015V1

Main Purpose
Power Management, Motor Control
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
ST7FMC2S4, STS8DNH3LL
Primary Attributes
3-Ph BLAC, BLDC, PMAC or PMDC Motors
Secondary Attributes
Graphical User Interface
Input Voltage
5 V to 48 V
Product
Power Management Modules
Silicon Manufacturer
ST Micro
Core Architecture
ARM
Core Sub-architecture
ARM7TDMI
Silicon Core Number
ST7
Silicon Family Name
ST7MCx
Kit Contents
Board
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
ST7MC2S4, STS8DNH3LL
Other names
497-8213

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STEVAL-IHM015V1
Manufacturer:
STMicroelectronics
Quantity:
135
UM0432
Note:
7.5.6
Table 15.
P1
P2
P3
P4
P1
P2
P3
P4
Sets the duty cycle percentage from 0% to the
maximum duty cycle allowed.
Sets the current reference value from 0 A to the
maximum current allowed.
During any state: idle, start, run or brake, a blinking red LED together with the brake of the
motor indicates a fault condition. A fault condition is due to one of the following:
Blinking of the red LED during the running of the motor indicates that a software current
limitation is in action.
Changing the real-time parameters
The real-time parameters can be changed using the potentiometers of the control board.
Table 15
Potentiometer functionality based on open/closed loop driving strategy
If during the GUI configuration phase the "from RV1" control was unchecked, the value of
the duty cycle (or the value of the current reference) is not set by P1 but has a fixed value.
If during the GUI configuration phase the "from RV2 - RV3" control was unchecked, the
value of the rising delay coefficient and the value of the falling delay coefficient are not set by
P2 and P3 but have fixed values.
The maximum duty cycle allowed in voltage mode depends on the value of the PWM
frequency and the value of the PWM minimum off time set by the GUI.
hardware overcurrent: current flowing inside the motor reaches a value greater than the
maximum allowed current of 7.65 A – see
Over-voltage: the bus voltage reaches a value greater than 29 Vac.
Over-temperature: the on-board temperature sensor measures a temperature greater
than 110° C.
Start-up failed: the start-up phase ends without getting a sufficient number of valid zero
crossing events.
Motor stalled: during the running of the motor no zero crossing events have been
observed.
explains the potentiometer functionality based on the driving strategy.
Open loop
Open loop
Sets the value of the falling delay coefficient from 0 to 255
Sets the value of the falling delay coefficient from 0 to 255
Sets the value of the rising delay coefficient from 0 to 255
Sets the value of the rising delay coefficient from 0 to 255
Current mode
Voltage mode
Not used
Not used
Sets the target rotor frequency value from the
minimum value to the maximum value configured
(see
Sets the target rotor frequency value from the
minimum value to the maximum value configured
(see
Section
Section
Section
7.4.16.
7.4.4)
7.4.4)
Closed loop
Closed loop
Motor control operations
39/53