CYII4SM6600-EVAL Cypress Semiconductor Corp, CYII4SM6600-EVAL Datasheet - Page 17

BOARD EVAL IMAGE SENS IBIS4-6600

CYII4SM6600-EVAL

Manufacturer Part Number
CYII4SM6600-EVAL
Description
BOARD EVAL IMAGE SENS IBIS4-6600
Manufacturer
Cypress Semiconductor Corp
Datasheet

Specifications of CYII4SM6600-EVAL

Sensor Type
CMOS Imaging, Monochrome
Sensing Range
6.6 Megapixel
Interface
SPI
Sensitivity
89 fps
Voltage - Supply
2.5 V ~ 3.3 V
Embedded
No
Utilized Ic / Part
IBIS4-6600
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Table 9. NDR: Advantages and Disadvantages
Sequencer and Registers
Figure 4
needed to operate the sensor in a particular sub sampling mode,
with a certain integration time, output amplifier gain, and more.
Most of these signals are generated on-chip by the sequencer
that uses only a few control signals. These control signals must
be generated by the external system:
Table 10. List of Internal Registers
Document Number: 001-02366 Rev. *G
Low Noise, because it is true CDS. In the order of 10 e- or below. System memory required to record the reset level and the
High Sensitivity, because the conversion capacitance is kept rather
low.
High Dynamic Range, because the results include signals for short
and long integrations times.
0 (0000)
1 (0001)
SYS_CLOCK, which defines the pixel rate (nominal 40 MHz),
Y_START pulse, which indicates the start of a new frame,
Y_CLOCK, which selects a new row and starts the row blanking
sequence, including the synchronization and loading of the
X-register.
Register
on page 6 showed several control signals that are
11:0
0
1:2
3
4
5
6
7
8
9
10
11
10:0
Bit
SEQUENCER
register
NDR
NDR_mode
RESET_BLACK
FAST_RESET
FRAME_CAL_MODE 0 = fast
LINE_CAL_MODE
CONT_CHARGE
GRAN_X_SEQ_LSB Granularity of the X sequencer clock
GRAN_X_SEQ_MSB
BLACK
RESET_ALL
NROF_PIXELS
Advantages
Name
Selection of mode, granularity of the X sequencer clock, calibration,
Default value <11:0>:"000100000000"
Mode of readout:
NDR = 0: normal readout (double sampling)
NDR = 1: non-destructive readout
4 different modes of nondestructive readout (no influence if NDR = 0)
0 = normal operation
1 = reset of pixels before readout
0 = electronic shutter operation
1 = addressing from both sides
1 = slow
0 = fast
1 = slow
0 = normal mode
1 = continuous precharge
0 = normal mode
1 = disconnects column amplifiers from buses, output of amplifier equals dark
reference level
0 = normal mode
1 = continuous reset of all pixels
Number of pixels to count (X direction). Max. 2222/2 (2210 real + 12 dummy pixels).
Default value <10:0>:"01000000000"
intermediate samples.
Requires multiples readings of each pixel, thus higher data
throughput.
Requires system level digital calculations.
The relative position of the pulses is determined by a number of
data bits that are uploaded in internal registers through a Serial
to Parallel interface (SPI).
Internal Registers
Table 10
registers are discussed in more detail in the following sections.
lists the internal registers with a short description. The
Description
IBIS4-6600 CYII4SM6600AB
Disadvantages
Page 17 of 34
[+] Feedback