AT91SAM7X256B-CU Atmel, AT91SAM7X256B-CU Datasheet - Page 187

IC MCU 256KB FLASH 100TFBGA

AT91SAM7X256B-CU

Manufacturer Part Number
AT91SAM7X256B-CU
Description
IC MCU 256KB FLASH 100TFBGA
Manufacturer
Atmel
Series
AT91SAMr

Specifications of AT91SAM7X256B-CU

Core Processor
ARM7
Core Size
16/32-Bit
Speed
55MHz
Connectivity
CAN, Ethernet, I²C, SPI, SSC, UART/USART, USB
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
62
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-TFBGA
Processor Series
91S
Core
ARM7TDMI
Data Bus Width
32 bit
Data Ram Size
64 KB
Interface Type
CAN, Ethernet, SPI, I2S, TWI, USART, USB
Maximum Clock Frequency
55 MHz
Number Of Programmable I/os
62
Number Of Timers
3
Operating Supply Voltage
3.3 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Operating Temperature Range
- 40 C to + 85 C
Package
100TFBGA
Device Core
ARM7TDMI
Family Name
91S
Maximum Speed
55 MHz
On-chip Adc
8-chx10-bit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7X256B-CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X256B-CU-999
Manufacturer:
Atmel
Quantity:
10 000
25.8
25.8.1
25.8.2
6120H–ATARM–17-Feb-09
Clock Switching Details
Master Clock Switching Timings
Clock Switching Waveforms
Table 25-1
selected clock to another one. This is in the event that the prescaler is de-activated. When the
prescaler is activated, an additional time of 64 clock cycles of the new selected clock has to be
added.
Table 25-1.
Figure 25-3. Switch Master Clock from Slow Clock to PLL Clock
To
Main Clock
SLCK
PLL Clock
Write PMC_MCKR
From
Master Clock
gives the worst case timings required for the Master Clock to switch from one
Slow Clock
PLL Clock
MCKRDY
Clock Switching Timings (Worst Case)
LOCK
PLLCOUNT x SLCK +
0.5 x Main Clock +
0.5 x Main Clock +
2.5 x PLLx Clock
AT91SAM7X512/256/128 Preliminary
Main Clock
4.5 x SLCK
4 x SLCK +
PLLCOUNT x SLCK
2.5 x PLL Clock +
2.5 x Main Clock
4 x SLCK +
5 x SLCK +
SLCK
PLLCOUNT x SLCK
2.5 x PLL Clock +
3 x PLL Clock +
3 x PLL Clock +
1 x Main Clock
4 x SLCK +
4 x SLCK +
PLL Clock
5 x SLCK
187