EP9307-CRZ Cirrus Logic Inc, EP9307-CRZ Datasheet - Page 37

IC ARM9 SOC ARM920T 272TFBGA

EP9307-CRZ

Manufacturer Part Number
EP9307-CRZ
Description
IC ARM9 SOC ARM920T 272TFBGA
Manufacturer
Cirrus Logic Inc
Series
EP9r
Datasheets

Specifications of EP9307-CRZ

Core Size
16/32-Bit
Core Processor
ARM9
Speed
200MHz
Connectivity
EBI/EMI, Ethernet, I²C, IrDA, Keypad/Touchscreen, SPI, UART/USART, USB
Peripherals
AC'97, DMA, I&sup2:S, LCD, LED, MaverickKey, POR, PWM, WDT
Number Of I /o
14
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 3.6 V
Data Converters
A/D 8x12b
Oscillator Type
External
Operating Temperature
0°C ~ 70°C
Package / Case
272-TFBGA
Controller Family/series
(ARM9)
No. Of I/o's
14
Ram Memory Size
32MB
Cpu Speed
200MHz
No. Of Timers
4
No. Of Pwm Channels
1
Digital Ic Case Style
TFBGA
Embedded Interface Type
AC97, I2S, SPI, UART, USB
Rohs Compliant
Yes
Processor Series
EP93xx
Core
ARM920T
Data Bus Width
32 bit
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2
Development Tools By Supplier
EDB9307A-Z
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1133 - KIT DEVELOPMENT EP9307 ARM9
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
 Details
Other names
598-1138

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP9307-CRZ
Manufacturer:
ALTERA
0
Part Number:
EP9307-CRZ
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
EP9307-CRZ/E2
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
EP9307-CRZ/IRZ
Manufacturer:
ALTERA
0
Part Number:
EP9307-CRZR
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
ADC
Using the ADC:
This ADC has a state-machine based conversion engine that automates the conversion process. The initiator for a
conversion is the read access of the TSXYResult register by the CPU. The data returned from reading this register
contains the result as well as the status bit indicating the state of the ADC. However, this peripheral requires a delay
between each successful conversion and the issue of the next conversion command, or else the returned value of
successive samples may not reflect the analog input. Since the state of the ADC state machine is returned through the
same channel used to initiate the conversion process, there must be a delay inserted after every complete conversion.
Note that reading TSXYResult during a conversion will not affect the result of the ongoing process.
The following is a recommended procedure for safely polling the ADC from software:
DS667PP3
Resolution
Integral non-linearity
Offset error
Full scale error
Maximum sample rate
Channel switch settling time
Noise (RMS) - typical
Note:
1. Read the TSXYResult register into a local variable to initiate a conversion.
2. If the value of bit 31 of the local variable is '0', repeat step 1.
3. Delay long enough to meet the maximum sample rate as shown above.
4. Mask the local variable with 0xFFFF to remove extraneous data.
5. If signed mode is used, do a sign extend of the lower halfword.
6. Return the sampled value.
ADIV refers to bit 16 in the KeyTchClkDiv register.
ADIV = 0 means the input clock to the ADC module is equal to the external 14.7456 MHz clock divided by 4.
ADIV = 1 means the input clock to the ADC module is equal to the external 14.7456 MHz clock divided by 16.
Parameter
Copyright 2004 Cirrus Logic (All Rights Reserved)
FFFF
61A8
0000
9E58
Figure 23. ADC Transfer Function
0
Range of 0 to 3.3 V
A/D Converter Transfer Function
No missing codes
(approximately ±25,000 counts)
Comment
ADIV = 0
ADIV = 1
ADIV = 0
ADIV = 1
Vref/2
ARM9 SOC with Ethernet, USB, Display and Touchscreen
50K counts (approximate)
Vref
Value
0.01%
0.2%
3750
±15
925
500
120
2
Samples per second
Samples per second
Units
mV
ms
µV
µs
EP9307
37

Related parts for EP9307-CRZ