ATMEGA169L-8MI Atmel, ATMEGA169L-8MI Datasheet - Page 277

no-image

ATMEGA169L-8MI

Manufacturer Part Number
ATMEGA169L-8MI
Description
IC MCU AVR 16K LV 8MHZ IND 64QFN
Manufacturer
Atmel
Series
AVR® ATmegar
Datasheets

Specifications of ATMEGA169L-8MI

Core Processor
AVR
Core Size
8-Bit
Speed
8MHz
Connectivity
SPI, UART/USART, USI
Peripherals
Brown-out Detect/Reset, LCD, POR, PWM, WDT
Number Of I /o
53
Program Memory Size
16KB (8K x 16)
Program Memory Type
FLASH
Eeprom Size
512 x 8
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-MLF®, 64-QFN
For Use With
ATAVRISP2 - PROGRAMMER AVR IN SYSTEMATAVRBFLY - KIT EVALUATION AVR BUTTERFLYATSTK502 - MOD EXPANSION AVR STARTER 500
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
ATMEGA169L-4MI
ATMEGA169L-4MI
Reading the Fuse and Lock
Bits
Reading the Signature Bytes
Reading the Calibration Byte
2514H–AVR–05/03
The algorithm for reading the Fuse and Lock bits is as follows (refer to “Programming
the Flash” on page 272 for details on Command loading):
1. A: Load Command “0000 0100”.
2. Set OE to “0”, BS2 to “0” and BS1 to “0”. The status of the Fuse Low bits can
3. Set OE to “0”, BS2 to “1” and BS1 to “1”. The status of the Fuse High bits can
4. Set OE to “0”, BS2 to “1”, and BS1 to “0”. The status fo the Extended Fuse bits
5. Set OE to “0”, BS2 to “0” and BS1 to “1”. The status of the Lock bits can now be
6. Set OE to “1”.
Figure 123. Mapping Between BS1, BS2 and the Fuse and Lock Bits During Read
The algorithm for reading the Signature bytes is as follows (refer to “Programming the
Flash” on page 272 for details on Command and Address loading):
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte (0x00 - 0x02).
3. Set OE to “0”, and BS to “0”. The selected Signature byte can now be read at
4. Set OE to “1”.
The algorithm for reading the Calibration byte is as follows (refer to “Programming the
Flash” on page 272 for details on Command and Address loading):
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte, 0x00.
3. Set OE to “0”, and BS1 to “1”. The Calibration byte can now be read at DATA.
4. Set OE to “1”.
now be read at DATA (“0” means programmed).
now be read at DATA (“0” means programmed).
can now be read at DATA (“0” means programmed).
read at DATA (“0” means programmed).
DATA.
Extended Fuse Byte
Fuse Low Byte
Fuse High Byte
Lock Bits
BS2
BS2
0
1
0
1
BS1
ATmega169V/L
0
1
DATA
277