SAF-XE167F-96F80L AC Infineon Technologies, SAF-XE167F-96F80L AC Datasheet - Page 103

no-image

SAF-XE167F-96F80L AC

Manufacturer Part Number
SAF-XE167F-96F80L AC
Description
IC MCU 16BIT FLASH 144-LQFP
Manufacturer
Infineon Technologies
Series
XE16xr
Datasheet

Specifications of SAF-XE167F-96F80L AC

Core Processor
C166SV2
Core Size
16-Bit
Speed
80MHz
Connectivity
CAN, EBI/EMI, I²C, LIN, SPI, SSC, UART/USART, USI
Peripherals
I²S, POR, PWM, WDT
Number Of I /o
118
Program Memory Size
768KB (768K x 8)
Program Memory Type
FLASH
Ram Size
82K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 24x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
144-LFQFP
Data Bus Width
16 bit
Data Ram Size
64 KB
Interface Type
CAN
Maximum Clock Frequency
66 MHz
Number Of Programmable I/os
118
Number Of Timers
11
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 24 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
SP000450816
4.6.4
The following parameters specify the behavior of the XE167 bus interface.
Table 27
Parameter
CLKOUT cycle time
CLKOUT high time
CLKOUT low time
CLKOUT rise time
CLKOUT fall time
1) The CLKOUT cycle time is influenced by the PLL jitter (given values apply to
Figure 21
Note: The term CLKOUT refers to the reference clock output signal which is generated
Data Sheet
For longer periods the relative deviation decreases (see PLL deviation formula).
CLKOUT
by selecting
P2.8 and by enabling the high-speed clock driver on this pin.
External Bus Timing
CLKOUT Reference Signal
CLKOUT Signal Timing
f
SYS
as the source signal for the clock output signal EXTCLK on pin
t
5
Symbol
t
t
t
t
t
5
6
7
8
9
CC
CC 3
CC 3
CC –
CC –
t
6
Min.
101
t
7
40/25/12.5
Limits
Max.
3
3
XE166 Family Derivatives
1)
t
8
f
SYS
Electrical Parameters
MC_X_EBCCLKOUT
Unit Note / Test
ns
ns
ns
ns
ns
= 25/40/80 MHz).
t
Condition
9
V2.1, 2008-08
XE167x

Related parts for SAF-XE167F-96F80L AC