TLE4262GM Infineon Technologies, TLE4262GM Datasheet - Page 4

no-image

TLE4262GM

Manufacturer Part Number
TLE4262GM
Description
IC REG LDO 5V 150MA DSO-14
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE4262GM

Regulator Topology
Positive Fixed
Voltage - Output
5V
Voltage - Input
Up to 45V
Voltage - Dropout (typical)
0.35V @ 150mA
Number Of Regulators
1
Current - Output
150mA (Max)
Current - Limit (min)
200mA
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
DSO-14
Number Of Outputs
1
Polarity
Positive
Input Voltage Max
45 V
Output Voltage
5 V
Output Type
Fixed
Dropout Voltage (max)
0.5 V at 150 mA
Output Current
200 mA
Line Regulation
25 mV
Load Regulation
25 mV
Voltage Regulation Accuracy
2%
Maximum Operating Temperature
+ 150 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
SP000012365
SP000306723
TLE4262GM
TLE4262GMTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE4262GM
Manufacturer:
INFINEON
Quantity:
1 533
Part Number:
TLE4262GM
Manufacturer:
INFINEON
Quantity:
2 861
Part Number:
TLE4262GM
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Circuit Description
The control amplifier compares a reference voltage, which is kept highly accurate by
resistance adjustment, to a voltage that is proportional to the output voltage and drives
the base of the series transistor via a buffer. Saturation control as a function of the load
current prevents any over-saturation of the power element. If the externally scaled down
output voltage at the reset threshold input drops below 1.35 V, the external reset delay
capacitor is discharged by the reset generator. If the voltage on the capacitor reaches
the lower threshold
again until the upper threshold
to GND, reset is triggered at an output voltage of 4.5 V. The IC can be switched at the
TTL-compatible, low-active inhibit input. It also includes a number of internal circuits for
protection against:
Figure 2
Data Sheet
Overload
Overtemperature
Reverse polarity
I
13
Adjustment
Block Diagram
V
Temperature
Reference
DRL
Bandgap
Sensor
, a reset signal is issued on the reset output and not cancelled
V
DU
Control
Amplifier
is exceeded. If the reset threshold input is connected
4
Buffer
INH
14
Control and
Saturation
Protection
Circuit
GND
3-5, 10-12
Generator
Reset
Rev. 2.8, 2008-05-19
AEB01081
9
6
7
1
TLE 4262
Q
D
RO
RADJ

Related parts for TLE4262GM