RN-134-K Roving Networks Inc, RN-134-K Datasheet - Page 18

KIT EVAL WIFLY GSX 802.11 RN-134

RN-134-K

Manufacturer Part Number
RN-134-K
Description
KIT EVAL WIFLY GSX 802.11 RN-134
Manufacturer
Roving Networks Inc
Type
Transceiver, 802.11 b/gr
Datasheets

Specifications of RN-134-K

Frequency
2.4GHz
Wireless Frequency
2402 MHz to 2480 MHz
Interface Type
RS-232, UART
Modulation
CKK, DSSS, DBPSK, DQPSK, OFDM
Security
128 WEP, WPA, TKIP
Operating Voltage
3 V to 12 V
Operating Temperature Range
- 40 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
RN-134
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
740-1035
set time port <num>
set time enable <value>
set uart baud <rate>
set uart instant <rate>
set uart raw <rate>
set uart flow <0,1>
set uart mode <mask>
*NOTE: When a TCP connection is closed, currently if there is RX data in the UART receiver, it is held
until
5.10. UART Parameters
www.rovingnetworks.com
809 University Avenue
This immediately changes the baudrate. This is useful when testing baudrate
Los Gatos, CA 95032
sets the time server port number. Defaults to 123 which is almost always
the sNTP server port.
Enable or disable fetching time from the specified sNTP time server.
Default=0= disabled. A value or 1 gets time only once on power up. Any
value > 1 gets time continuously every <value> minutes.
set the UART baud rate. Valid settings are {2400, 4800, 9600, 19200,
38400, 57600, 115200, 230400, 460800, 921600}.
Example : “set u b 9600” sets the baud rate to 9600 baud.
NOTE: the RS232 interface on the RN-134 does not work above 230400
settings, or switching baudrate “on the fly” remotely while connected over
TCP. This setting does not affect configuration. Returns the AOK
response, and then this command will exit command mode.
sets a RAW UART value. Used to set non-standard rates. The lowest
possible baud rate is 2400.
Example : “set u r 7200” sets the baud rate to 7200 baud.
sets the flow control mode. Default=0=off, 1= hardware RTS/CTS.
NOTE: once flow control is enabled, it is important to properly
Drive the CTS pin (active LOW enabled) If CTS is HIGH, data will
NOT be sent out the UART, and further configuration in command mode
will be problematic as no response will be received.
sets the UART mode register. This is a bit-mapped value.
Bit Position
0
1
2
3
4
~ 18 ~
Function
NOECHO - disables echo of RX data while in
command mode
DATA TRIGGER makes connection on RX data
RAW mode (TCP stack disabled )
Enable Sleep on RX BREAK signal
UART RX data buffer. See note below for details*
Tel (408) 395-6539
• info@RovingNetworks.com
WiFlyGSX-um
WiFly GSX
9/16/2010