EM260-RTR Ember, EM260-RTR Datasheet - Page 85

IC ZIGBEE SYSTEM-ON-CHIP 40-QFN

EM260-RTR

Manufacturer Part Number
EM260-RTR
Description
IC ZIGBEE SYSTEM-ON-CHIP 40-QFN
Manufacturer
Ember

Specifications of EM260-RTR

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
ZigBee™
Power - Output
-32dBm ~ 3dBm
Sensitivity
-97dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
30mA
Current - Transmitting
34mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
40-QFN
For Use With
636-1009 - PROGRAMMER USB FLASH EM250/260
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Other names
636-1007-2
EM260-RTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EM260-RTR
Manufacturer:
UNISEM
Quantity:
120
Part Number:
EM260-RTR
0
6.4.2
1)
6.4.3
1)
2)
3)
HOST -> EM260: | 00 | 06 |
frame control
stackStatusHandler response = 0x19
status
EM260 -> HOST: | 80 | 19 | 90 |
frame control
setBinding command = 0x2B
index
type
local
remote
clusterId
identifier
HOST -> EM260: | 00 | 2B | 00 | 01 | 11 | 12 | 55 | 88 | 77 | 66 | 55
frame control
setBinding response = 0x2B
status
EM260 -> HOST: | 80 | 2B | 00 |
frame control
sendDatagram command = 0x37
bindingTableIndex
clusterId
messageTag
messageLength
messageContents
HOST -> EM260: | 00 | 37 | 00 | 55 | 01 | 03 | E1 | E2 | E3 |
frame control
sendDatagram response = 0x37
status
EM260 -> HOST: | 80 | 37 | 00 |
Host waits for callback signal while EM260 tries to send the message.
frame control
callback command = 0x06
HOST -> EM260: | 00 | 06 |
frame control
messageSent response = 0x3F
bindingTableIndex
clusterId
messageTag
status
EM260 -> HOST: | 80 | 3F | 00 | 55 | 01 | 00 |
Binding
Sending
| 44 | 33 | 22 | 11 |
= 0x00 (command frame, don't sleep)
= 0x00 (command frame, don't sleep)
= 0x00
= 0x01 (EMBER_UNICAST_BINDING)
= 0x11
= 0x12
= 0x55
= 0x1122334455667788
= 0x80 (response frame, no overflow, not truncated)
= 0x00 (EMBER_SUCCESS)
= 0x00 (command frame, don't sleep)
= 0x00
= 0x55
= 0x01
= 0x03
= 0xE1, 0xE2, 0xE3
= 0x80 (response frame, no overflow, not truncated)
= 0x00
= 0x55
= 0x01
= 0x00 (EMBER_SUCCESS)
= 0x80 (response frame, no overflow, not truncated)
= 0x00 (EMBER_SUCCESS)
= 0x80 (response frame, no overflow, not truncated)
= 0x90 (EMBER_NETWORK_UP)