Specifications of IDTTSE2002B3CNCG8

Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Control Logic, Register Bank
Sensor Type
Internal
Sensing Temperature
-20°C ~ 125°C
Output Type
2-Wire Serial, I²C™/SMBUS™
Output Alarm
No
Output Fan
No
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-20°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-WFDFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
800-2034-2
Software Write Protect
temporarily or permanently write protected.
Result of Setting the Write Protection
SWP and CWP
Operating Modes table). Like the Byte Write instruction, it is followed by an address byte and a data byte, but in this case the contents are all “Don't
Care” (refer to the Setting the Write Protection figure). Another difference is that the voltage, V
levels must be applied on the other two (SA1 and SA2, as shown in the I
PSWP
write-protection cannot be cleared by any instruction, or by power-cycling the device. Also, once the PSWP instruction has been successfully
executed, the TSE2002B3C no longer acknowledges any instruction (with a Device Type Identifier of 0110) to access the write-protection settings.
The TSE2002B3C has three software write-protection features, allowing the bottom half of the memory area (addresses 0x00 to 0x7F) to be
Software write-protection is handled by three instructions:
SWP: Set Write Protection
CWP: Clear Write Protection
PSWP: Permanently Set Write Protection
The level of write-protection (set or cleared) that has been defined using these instructions, remains defined even after a power cycle.
If the software write-protection has been set with the SWP instruction, it can be cleared again with a CWP instruction.
The two instructions (SWP and CWP) have the same format as a Byte Write instruction, but with a different Device Type Identifier (refer to the I
If the software write-protection has been set with the PSWP instruction, the first 128 bytes of the memory are permanently write-protected. This