Datasheet

Specifications of TLE4906H

Sensing Range
13.9mT Trip, 4.7mT Release
Voltage - Supply
2.7 V ~ 18 V
Current - Supply
6mA
Current - Output (max)
20mA
Output Type
Digital, Differential
Operating Temperature
-40°C ~ 150°C
Package / Case
TO-236-3, SC-59, SOT-23-3
Operating Supply Voltage
3.3 V or 5 V or 9 V or 12 V or 15 V
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 150 C
Minimum Operating Temperature
- 40 C
Maximum Output Current
20 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
SP000012950
TLE4906HXT
TLE4906HXT
Edition 2005-10
Published by Infineon Technologies AG,
St.-Martin-Strasse 53,
81669 München, Germany
©
Infineon Technologies AG 2005.
All Rights Reserved.
Attention please!
The information given in this document shall in no event be regarded as a guarantee of conditions or
characteristics (“Beschaffenheitsgarantie”). With respect to any examples or hints given herein, any typical values
stated herein and/or any information regarding the application of the device, Infineon Technologies hereby
disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-
infringement of intellectual property rights of any third party.
Information
For further information on technology, delivery terms and conditions and prices please contact your nearest
Infineon Technologies Office (www.infineon.com).
Warnings
Due to technical requirements components may contain dangerous substances. For information on the types in
question please contact your nearest Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or systems with the express written
approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure
of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support
devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain
and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may
be endangered.

Related parts for TLE4906H