C40K-CDR-A Omron, C40K-CDR-A Datasheet - Page 127

no-image

C40K-CDR-A

Manufacturer Part Number
C40K-CDR-A
Description
PROGRAMMABLE CONTROLLER CPU
Manufacturer
Omron
Datasheet

Specifications of C40K-CDR-A

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Data Conversion
5-15-3
116
Limitations
Description
Digit Designator
4-TO-16 DECODER – MLPX(76)
The rightmost two digits of Di must each be between D and 3.
All result words must be in the same data area.
When the execution condition is OFF, MLPX(76) is not executed and the next
instruction is moved to. When the execution condition is ON, MLPX(76) con-
verts up to four, four-bit hexadecimal digits from S into decimal values from 0
to 15, each of which is used to indicate a bit position. The bit whose number
corresponds to each converted value is then turned ON in a result word. If
more than one digit is specified, then one bit will be turned ON in each of
consecutive words beginning with R. (See examples, below.)
The following is an example of a one-digit decode operation from digit num-
ber 1 of S, i.e., here Di would be 0001.
The first digit and the number of digits to be converted are designated in Di. If
more digits are designated than remain in S (counting from the designated
first digit), the remaining digits will be taken starting back at the beginning of
S. The final word required to store the converted result (R plus the number of
digits to be converted) must be in the same data area as R, e.g., if two digits
are converted, the last word address in a data area cannot be designated; if
three digits are converted, the last two words in a data area cannot be desig-
nated.
The digits of Di are set as shown below.
Ladder Symbol
Digit numbers: 0 1 2 3
MLPX(76)
Di
R
S
0
0
0
1
0
S
Bit C (i.e., bit number 12) turned ON.
0
C
Specifies the first digit to be converted (0 to 3)
Number of digits to be converted (0 to 3)
0: 1 digits
Not used.
0
0
R
0
0
1: 2 digits
2: 3 digits
3: 4 digits
0
Operand Data Areas
0
IR, SR, DM, HR, TC
Di : Digit designator
R : First result word
IR, DM, HR, TC, #
S : Source word
0
IR, DM, HR
0
0
Section 5-15
0

Related parts for C40K-CDR-A