Scale Display
Scale:
Distance:
Scale Length: Specify the scale length in % format regarding the radius as
No. of Division: Specify the number of the division that the scale should be di-
Scale Color:
Color
Foreground:
Background: Specify the background color of the circumscribed rectangle of an
+Range:
–Range:
Settings
Value
Table Entry: Specify the table entry number of a numeral memory table entry to
Display %:
100%
Table Entry: Specify this item if a 100% value is set by a numeral memory table
Value:
0%
Table Entry: Specify this item is a 0% value is set by a numeral memory table
Value:
–100%
Table Entry: Specify this item if a –100% value is set by a numeral memory table
Specify the color of analogue meter displayed for a positive value.
Specify the color of analogue meter displayed for a negative value.
Specify whether or not a percent value is displayed on the screen.
Specify this item if a 100% value is set by a constant; set the value
Specify this item if a 0% value is set by a constant; set the value to
analogue meter. (Can only be set for PTs with color display.)
Transparent, white, black, blue, red, magenta, green, cyan, yellow
(Can only be set for PTs with color display.)
White, black, blue, red, magenta, green cyan, yellow
(Can only be set for PTs with color display.)
White, black, blue, red, magenta, green, cyan, yellow
be displayed.
entry; set the table entry number of the numeral table.
to be taken for a 100% value.
entry; set the table entry number of the numeral table.
be taken for a 0% value.
entry; set the table entry number of the numeral table.
Specify whether or not a scale is displayed for an analogue me-
Specify the scale position in % format regarding the radius as
Specify the color for displaying the present value.
ter.
100%.
0 to 150 (by 1%)
100%.
10 to 110 (by 1%)
vided in the range from 0 to 100%.
1 to 20
Specify the scale color of an analogue meter.
(Can only be set for PTs with color display.)
White, black, blue, red, magenta, green, cyan, yellow
(Can only be set for PTs with color display.)
White, black, blue, red, magenta, green, cyan, yellow
Section
6-9