Data Conversion
Correction related the reference memory table entires for numeral input
Correction related to an interlock function of a touch switch, numeral/string input, or thumbwheel
Correction related the number of digits for numeral display
In the conversion of the data between a conventional and a new model, conver-
sion is executed in the manner shown below due to differences in the numeral
memory table entries that can be referred to.
S Difference
S Conversion result, error message and corrective action
In the conversion of the data between a V2 model and a non-V2 model/conven-
tional model, conversion is executed in the manner shown below due to an inter-
lock function, that has been added to V2 models.
S Difference
S Conversion result, error message and corrective action
In the conversion of the data between a conventional and a new model, conver-
sion is executed in the manner shown below due to differences in the range of
numeric values that can be displayed.
S Difference
New models:
Conventional models:
V2 models: Operations/Inputs can be enabled/disabled according to the status
of the host bit (interlock bit).
Conventional models, non-V2 models: Interlock bit can not be set.
New models:
Conventional models:
With a conventional
model, a numeral
setting input field (or
a thumbwheel
switch) for which a
numeral memory
table in the range
No. 247 to No. 253
is referred to is reg-
istered to the sym-
bol manager.
With V2 models, an
object allocated an
interlock function is
registered in the
symbol manager.
Status before
Status before
Conversion
Conversion
With a new model,
the reference nu-
meral memory table
No. is corrected to
0.
With non-V2 mod-
els/conventional
models, an interlock
bit setting will be
discarded.
Status after
Status after
Conversion
Conversion
For numeral memory table entries No. 247 to No.
253, reference is not possible for numeral input/
thumbwheel switch.
For numeral memory table entries No. 247 to No.
253, reference is possible for numeral input/thumb-
wheel switch. (Display only)
A numeric value of up to 10 digits can be displayed.
A numeric value of up to 8 digits can be displayed.
Thumbwheel switch
refers to reserved
numeral table entry.
The referenced
table entry is reset
to 0.
Interlock not sup-
ported. Interlock
setting will be dis-
carded.
Error Message
Error Message
Make corrections so that
the contents of a numer-
al memory table in the
range No. 247 to No.
253 are displayed in a
numeral display. (Refer
to 6-6 Numeral Display.)
Screen switching, nu-
meral/string input at PT
side can be enabled/dis-
abled using the PT con-
trol bit in PT control area
also. Modify the pro-
gram according to the
setting.
Corrective Action
Corrective Action
Appendix A