NT600SST211BEV3 Omron, NT600SST211BEV3 Datasheet - Page 482

no-image

NT600SST211BEV3

Manufacturer Part Number
NT600SST211BEV3
Description
Controllers, Display
Manufacturer
Omron
Datasheet

Specifications of NT600SST211BEV3

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Lead free / RoHS Compliant
Data Conversion
Correction related to contents of numeral memory table
Correction related to bit memory table
470
S Difference
S Conversion result, error message and corrective action
When the data of a conventional model is converted to the data for a new model,
the converted data requires your attention to the fact that the processing that oc-
curs if incorrect data (existence of A to F other than F at the most significant bit
position) is written to an allocated word in the host differs between a conventional
and a new model.
S Difference
S Conversion result, error message and corrective action
If a bit memory table is converted from the conventional model to the new model,
conversion will be executed in the manner shown below due to the difference of
the bit memory table function.
New models:
Conventional models:
A memory table
number that is out-
side the allowable
range for the
memory table is
used for display or
input.
string memory
memory table
Extended I/O
Extended I/O
table (String
output table
Bit memory
F-key input
notify table
input table
Character
Status before
Status before
Numeral
Conversion
Conversion
table)
table
––
NT11S/
NT11
128
128
––
––
––
4
The memory table
number is reset to
0.
Status after
Status after
Conversion
Conversion
The written data is invalid and the existing content is
retained.
The incorrect data is stored.
––
NT20S
128
128
––
––
––
––
NT600S
[Object Name] re-
fers to invalid nu-
meral table entry.
The referenced
table entry is reset
to entry 0.
512
256
––
––
––
––
Error Message
Error Message
––
NT30C
512, or
256, or
NT30
1000
1000
256
64
64
––
Correct the memory
table number to the one
that is in the valid range.
If the memory table
number is specified in a
program, correct it also.
(Refer to Dialog Box
Settings in the PT Con-
figuration on page 45.)
Note that the display dif-
fers between a conven-
tional and a new model
if incorrect data is writ-
ten. (Refer to 7-2 Nu-
meral Memory Table.)
NT620C
NT625C
NT620S
512, or
256, or
Corrective Action
Corrective Action
1000
1000
256
––
––
––
Appendix A
NT631C
1000, or
1000, or
NT31C
256, or
NT631
NT21
NT31
2000
2000
1000
512,
256,
––
––
––

Related parts for NT600SST211BEV3