NT600SST211BEV3 Omron, NT600SST211BEV3 Datasheet - Page 476

no-image

NT600SST211BEV3

Manufacturer Part Number
NT600SST211BEV3
Description
Controllers, Display
Manufacturer
Omron
Datasheet

Specifications of NT600SST211BEV3

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Lead free / RoHS Compliant
Data Conversion
Correcting the Screen Data Conversion
Correcting the NT11, NT21, NT31, NT31C, NT631, NT631C screen data after conversion
464
NT30, NT30C,
NT620S, NT620C,
NT625C
NT20S
NT30, NT30C,
NT620S, NT620C,
NT625C
Convert From
NT31, NT31C,
NT631, NT631C with
“-V1” *1
NT21
NT31, NT31C,
NT631, NT631C with
“-V2” *2
Convert To
(4) Correct the screen data
(5) Modify the program.
This section describes how the screen data should be corrected after it has been
converted.
If the screen data cannot be converted correctly, an error message is displayed
on conversion of the data (when changing a PT model or PLC Vendor, or register-
ing a symbol from the symbol manager). If an error message is displayed, it will
be necessary to correct the screen data or the program.
If the screen data is converted to the NT21, NT31, NT31C, NT631 or NT631C,
the following modification of the screen data and program is needed according to
the source/destination PT model.
between different direct access types, modification of the allocated bits and
words may become necessary since the range of usable word addresses
differ. For details, refer to Correcting the PC (PLC) addresses on page 466.
If the data is converted from a PT model to another PT model that has small-
er screen than the source PT model, it is necessary to modify the screen
data in accordance with the screen size.
If data is converted between a conventional model and a new model, the
data must be corrected in accordance with the conversion destination be-
cause there are many differences between a conventional model and a new
model.
Refer to page 464.
If the screen data is corrected, the program at the host may have to be modi-
fied. Modify the program by referring to “Correcting the Screen Data Conver-
sion” (page 464).
S If image/library is inserted into a lamp/touch switch label or a character
S Word configuration of PT control/notify area differs between the source
S If a keyboard screen is used, the size of the keyboard screen frame
S Word configuration of PT control/notify area differs between the source
S Some changes will occur on the screens, such as in the sizes of touch
If a keyboard screen is used, the size of the keyboard screen frame
needs to be checked/adjusted. For how to perform the correction, refer
to Correction related to keyboard screens (page 467).
string, modification of screen data is needed. For how to perform the
correction, refer to Correction of image codes (page 471) or Correction
of library codes (page 472).
and destination PT model. Check the program at the host and make
corrections. For details, refer to Appendix A NT20/30/620 compatible
mode.
needs to be checked/adjusted. For how to perform the correction, refer
to Correction related to keyboard screens (page 467).
and destination PT model.
Check the program at the host and make corrections. For details, refer
to Appendix A NT20/30/620 Compatible Mode.
switches and the positions of objects, check all converted screens and
correct them as necessary.
Modification needed
Appendix A