2ED300E17-S Infineon Technologies, 2ED300E17-S Datasheet - Page 6

Power Management Modules & Development Tools DUAL CH EVAL BD IGBT DRV 2ED300C17-S

2ED300E17-S

Manufacturer Part Number
2ED300E17-S
Description
Power Management Modules & Development Tools DUAL CH EVAL BD IGBT DRV 2ED300C17-S
Manufacturer
Infineon Technologies
Type
MOSFET & Power Driverr
Datasheet

Specifications of 2ED300E17-S

Input Voltage
1700 V
Board Size
125 mm x 70 mm
Product
Power Management Modules
Dimensions
125 mm x 70 mm
For Use With/related Products
2ED300C17-S
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Reset: Switch S1 and X1/Pin5
By the use of a Reset switch S1 or with a positive
edge greater than10V on X1/5 the driver is reset
in case of a fault.
Fault output: LED D1 and x1/Pin3
In case of a fault the red LED is turned on and the
the output and corresponding output X1/3 goes to
Low (negative logic)
Modus: X1/12
Two modes may be chosen: the half-bridge mode
and the direct mode.
The half-bridge mode is activated as X1/12 is
connected to +15V
The direct mode is activated as X1/12 is
connected to GND.
See also the datasheet of the 2ED300C17-S
chapter 3.2
Interlock times : CA and CB
Interlock delay times in the half-bridge mode are
set with capacitors C4 and C5. Preset is approx.
4.5µs.
2ED300C17S chapter 3.3
www.eupec.com
Using and adapting:
See
EiceDRIVER
EiceDRIVER
NOTE ! The PWM inputs have a trigger level of +10V.
Technische Information / Technical Information
also
the
datasheet
www.EiceDRIVER.com
of
the
2ED300E17-S
Soft Shut Down: R
The R
performance of the SSD depends on the R
has to be adapted. See also the datasheet of the
2ED300C17-S chapter 3.8.
V
The V
with the components C12,C13 and R7,R8. See also
the datasheet of the 2ED300C17-S chapter 3.7
V
By changing the values of C10, C11 and R5,R6 the
trigger level of the V
See also the datasheet of the 2ED300C17-S
chapter 3.7.
CE sat
CE sat
CE sat
Reference curve : C
Trigger suppression : C
SSD
reference curve for phase U can be set
R4/R3 is preset to 10kOhm. The
SSD
CE sat
monitoring can be set.
SX
and R
VCE
Seite/Page 6
and R
SX
VCE
SSD
and

Related parts for 2ED300E17-S