F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Safety Precautions
The following information is intended as a guide for selecting the F3SX Safety Controller.
Be sure to read the User’s Manual for the product (SCHG-705) before use.
Overview
Regulations and Standards
The F3SX is designed for use by authorized personnel who
thoroughly understand the installed machinery.
The use of “authorized personnel” in the User’s Manual
(SCHG-705) refers to personnel qualified and authorized to secure
safety across all phases of the safety life cycle from machinery
design through, installation, operation, maintenance, and disposal.
The specified installation environment and machinery performance
characteristics of the F3SX are applicable under correct usage
conditions. Have a related organization perform risk assessment
before selecting, installing, or setting the F3SX.
Be sure to thoroughly read and understand the User’s Manual for
the product (SCHG-705) before use and always use the product
correctly according to the manual.
“Type Approval” specified in Chapter 44.2 of the Industrial Safety
and Health Law in Japan does not apply to independent
Controllers. This law applies to systems incorporated with the
F3SX Controllers. Therefore, when using the F3SX Controllers in
Japan as “safety devices for presses or shearing machines” as
specified in Chapter 42 of the same law, apply for approval as a
system.
Install the reset switch in a location from which the entire
hazardous area is visible and where the switch cannot be operated
from within the hazardous area.
Connect control devices that are suitable for the required safety
functions. Using unsuitable external devices may result in the
F3SX not being capable of performing safety functions fully.
The DC Power Supply Unit must satisfy all of the following
conditions for the F3SX to meet EN60204-1, IEC61496-1, and
UL508 standards.
• The power supply voltage is within the rating (24 VDC ± 10%).
• The power supply is used to supply the F3SX and its connected
• The power supply conforms to the EMC Directive (industrial
• The power supply uses double or reinforced insulation between
• The power supply automatically resets overcurrent protection
• The power supply maintains an output holding time of at least
• The power supply must have output characteristics of Class 2
• The power supply must conform to regulatory requirements and
When using a commercially available switching regulator, make
sure FG (frame ground terminal) is connected. Faulty operation
caused by switching noise may result if the terminal is not
connected.
Sensors only, and is not connected to any other devices or
equipment. When connecting multiple devices, make sure the
total rated current is not exceeded.
environment).
the primary and secondary circuits.
characteristics (voltage drop).
20 ms.
Circuit or Limited Voltage-Current Circuit as defined in UL508.
standards regarding EMC and electrical equipment safety of the
country where the F3SX is installed.
Example: The EMC Directive (industrial environment) and the
Low Voltage Directive in EU.
http://www.ia.omron.com/
!WARNING
1. EU Regulations
2. European Standards
3. International Standards
The F3SX is electro-sensitive protective equipment (ESPE) in
accordance with European Union (EU) Machinery Directive Annex
IV, B, Safety Components, Item 1 and Item 2.
The F3SX received the following approvals from TÜV-Product
Service.
Machinery Directive: Directive 98/37/EC
Low Voltage Directive: Directive 73/23/EEC
EMC Directive: Directive 89/336/EEC
EN61508 (SIL1-3), EN954-1 (Category 4, 3, 2, 1, B), EN61496-1
(TYPE 4 ESPE), EN50178, EN55011, EN60204-1, EN61000-6-2,
EN61000-6-4, EN1760, EN574 (Type III C), EN1088
IEC61508 (SIL1-3), IEC61496-1 (Type 4 ESPE), IEC60204-1
The F3SX received the following approvals from the Third Party
Assessment Body UL:
Certificate of UL listing for US and Canadian safety standards:
UL508, UL1998, UL61496-1 (Type 4 ESPE), CSA C22.2 No. 14,
CSA C22.2 No.0.8
Do not connect a DC or AC power supply output that exceeds the
rated value to the power supply input of the F3SX.
Connect a fuse serially to the output contact of the relay output.
Do not use a load that exceeds the switching capacity. Doing so
may result in damage to the output circuits and the F3SX may not
be capable of turning OFF.
Take measures to prevent common malfunctions that would
disable all redundant safety circuits at the same time.
Do not use the F3SX’s PLC communications functions to configure
a safety system. Doing so may result in serious injury due to faulty
wiring or PLC malfunction.
Do not attempt to disassemble, repair, or modify the F3SX.
Otherwise, the F3SX may not be capable of performing its safety
functions.
Wire the I/O terminals correctly. Incorrect wiring may result in
electric shock or the safety functions may be damaged.
Do not use the auxiliary outputs to configure a safety system.
Using the auxiliary outputs as safety outputs may result in serious
injury if the F3SX or peripheral devices malfunction.
Do not connect input devices to the auxiliary input terminal (start
command input) to configure a safety system. Doing so may result
in serious injury if the F3SX or peripheral devices malfunction.
(c)Copyright OMRON Corporation 2008 All Rights Reserved.