F39-EU1E Omron, F39-EU1E Datasheet - Page 67

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Safety Precautions
Refer to the “Precautions for All Relays” and “Precautions for All Relays with Forcibly Guided Contacts”.
Appricable Safety Category (EN954-1)
G9SA-300-SC Safety Relay Units fall under Safety Category 4.
The above is provided according to circuit examples presented by
OMRON. Therefore, the above may not apply to all operating
environments.
The applicable safety category is determined from the whole safety
control system. Make sure that the whole safety control system meets
EN954-1 requirements.
Turn OFF the G9SA-300-SC before wiring the G9SA-300-SC. Do
not touch the terminals of the G9SA-300-SC while the power is
turned ON, because the terminals are charged and may cause an
electric shock.
To conform to IEC61496-1 and UL508 when using the F3SN-A,
F3SN-B, or F3SH-A, ensure that the DC power supply satisfies all
the conditions below.
• The voltage is within the rated power supply voltage range
• The power supply is connected only to the F3SN-A or devices
• The power supply conforms to the EMC Directive (industrial
• The power supply uses double or reinforced insulation between
• The power supply automatically resets overcurrent protection
• The power supply maintains an output holding time of at least
• The power supply satisfies the output characteristic
• The power supply satisfies laws, regulations, and standards
Recommended Power Supplies: S82K, S82J, S82F, or S82F-P
made by OMRON. For details, refer to the Power Supply Selection
Guide (Cat. No. Y102).
Do not connect any device other than the F3SN-A, F3SN-B, or
F3SH-A with PNP outputs.
Be sure to mount both the emitter and the receiver in the correct
position. (The Sensor will not operate it they are mounting in
reverse.)
For further details on using the F3SN-A, F3SN-B, or F3SH-A, refer
to F3SN-A/F3SN-B, or F3SH-A.
(24 VDC 10%).
with a direct bearing on the F3SN-A’s electrical detection
protective function, such as Safety Controllers or Muting
Sensors. Do not connect it to any other devices or equipment.
When connecting more than one device, ensure that the
capacity is easily sufficient for the total rated current.
environment).
the primary and secondary circuits.
characteristics (voltage drop).
20 ms.
requirements of limited voltage/current circuits and Class 2
circuits as defined by UL508.
concerning EMC and the safety of electrical devices for the
country or region in which it is used. (In the EU, for example, the
power supply must conform to the EMC Directive and Low
Voltage Directive.)
Precautions for Safe Use
http://www.ia.omron.com/
Installation
The G9SA-300-SC can be installed in any direction.
Wiring
Connecting Inputs
When using more than one G9SA300-SC Unit, do not connect the
same switch to more than one G9SA300-SC Unit. This applies to all
input terminals.
Durability of Contact Outputs
Relay with Forcibly Guided Contact durability depends greatly on the
switching condition. Confirm the actual conditions of operation in
which the Relay will be used in order to make sure the permissible
number of switching operations.
When the accumulated number of operation exceeds its permissible
range, it can cause failure of reset of safety control circuit. In such
case, please replace the Relay immediately. If the Relay is used
continuously without replacing, then it can lead to loss of safety
function.
Certified Standards
The G9SA-300-SC conforms to the following standards.
Use the following to wire the Unit.
Stranded wire: 0.75 to 1.5 mm
Solid wire:
Tighten each screw to a torque of 0.78 to 1.18 N·m, or the Unit may
malfunction or generate heat.
External inputs connected to H1 and T12 or T21 and T22 of the
Unit must be no-voltage contact inputs.
GND is a ground terminal. When a machine is grounded at the
positive, the GND terminal cannot be grounded.
EN standards, certified by TÜV Rheinland
EN954-1
EN60204-1
Conformance to EMC (Electromagnetic Compatibility), certified by
TÜV Rheinland:
EMI (Emission): EN55011 Group 1 Class A
EMS (Immunity): EN61000-6-2
UL standards: UL508 (Industrial Control Equipment)
CSA standards: CSA C22.2 No. 14 (Industrial Control Equipment)
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Precautions for Correct Use
Incorrect
1.0 to 1.5 mm
T11 T12
G9SA
-300-SC
2
2
T11 T12
G9SA
-300-SC
G9SA-300-SC
8