F39-EU1E Omron, F39-EU1E Datasheet - Page 523

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Wiring
Circuit Connection Example
Wiring
[Reference] Crimp Terminals
Manufacturer
J.S.T. Mfg Co.
E1
(+)
E2
(−)
O1
(+)
O2
(−)
Direct opening contacts used for safety circuit inputs are indicated
with the
opening contacts.
Connect the indicators in parallel to the auxiliary circuits or
terminals E1 and E2. Do not connect the indicators in parallel with
the direct opening contact. If the indicators are broken, a
short-circuit current may flow, causing equipment to malfunction.
Do not switch circuits for two or more standard loads at the same
time. Doing so may adversely affect insulation performance.
The 24 VDC solenoid terminals have polarity (E1: +, E2: ).
Confirm the polarity before wiring.
The contact ON/OFF timing for Switches is not synchronized.
Confirm performance before application.
Do not wire the Switch while power is being supplied. Doing so may
result in electric shock.
Do not let particles, such as small pieces of lead wire, enter the
switch body when wiring.
Make sure that the wiring does not hide the LED indicator when
wiring E1/E2 or O1/O2.
When connecting to the terminals via insulating tube and M3.5
crimp terminals, arrange the crimp terminals so that they do not
rise up onto the case or the cover.
Applicable lead wire size: AWG22 to AWG18 (0.3 to 0.75 mm
Use lead wires of an appropriate length. Not doing so may result in
excess length causing the cover to rise and not fit properly.
Do not pull on the lead wires with excessive force. Doing so may
disconnect them.
Do not push crimp terminals into gaps in the case interior. Doing so
may cause damage or deformation of the case.
Crimp terminal
LED
dz dia: 4.3 mm
D dia: 4.0 mm
Lock Monitor
Switch
B: 6.6 mm
F: 6.3 mm
L: 18.6 mm
t: 0.8 mm
I: 9.0 mm
mark. Terminals 12-41 and terminals 22-51 have direct
Correct
41
51
61
FN1.25-M4 (F Type)
N1.25-M4 (Straight Type)
http://www.ia.omron.com/
Terminal screw
D dia.
42
52
62
Model
l
Door Open/Closed
Detection Switch
11
21
31
L
F
dz dia.
12
22
32
Incorrect
B
To safety circuit
To safety circuit
To control circuit
To control circuit
2
).
Processing the Conduit Opening
Recommended Connectors
Use a connector with a screw section not exceeding 9 mm.
Otherwise, the screws will protrude into the case interior. The
connectors given in the following table have connectors with screw
sections not exceeding 9 mm. Use the following connectors to ensure
conformance to IP67.
Use LAPP connectors together with Seal Packing (JPK-16, GP-13.5,
or GPM20), and tighten to the applicable torque. Seal Packing is sold
separately.
Other Precautions
G1/2
PG13.5
M20
1/2-14NPT
Connect a recommended connector to the opening of the conduit
and tighten the connector to the proper torque. The case may be
damaged if excessive tightening torque is applied.
When using a 1/2-14NPT conduit, wind sealing tape around the
conduit end of the connector so that the enclosure will conform to
IP67.
Make sure that the outer diameter of the cable connected to the
connector is correct.
Attach a conduit cap to the unused conduit opening when wiring
and tighten it to a suitable torque. The conduit cap is provided with
the Switch.
LAPP is a German manufacturer.
For a 1/2-14NPT conduit, use the above connector after attaching
the provided Adaptor to the Switch and wrapping it with sealing
tape.
A Guard Lock Safety-door Switch will heat when power is supplied
to the solenoid. Do not touch these Switches.
Size
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
LAPP
LAPP
LAPP
LAPP
Manufacturer
ST-PF1/2
ST-13.5
ST-M20
ST-NPT1/2
1.5
Model
5380-1002
5301-5030
5311-1020
5301-6030
6.0 to 12.0 mm
6.0 to 12.0 mm
7.0 to 13.0 mm
6.0 to 12.0 mm
Applicable
diameter
cable
D4JL
23