F39-EU1E Omron, F39-EU1E Datasheet - Page 585

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Response Time and Operating Time
1. G9SX-NS@
2. G9SX-NSA@
3. Multiple G9SX-NS@/NSA@ Non-contact Door Switch Controllers
Logical AND
Logical AND
Logical AND input
Logical AND input
When multiple Controllers are logically connected with AND connections, the response time is the sum of the response times given in 1 and 2
above. (It is the same for the operating time.)
(1)
(2)
Non-contact Door
Switch input
D40A (1)
D40A (2)
D40A (3)
http://www.ia.omron.com/
Non-contact Door
Switch input
Safety output (2)
Safety output (3)
Safety output
D4NS
Safety input
D4NS
Safety input
(1)
*1. The maximum response time is the time it takes the output to switch from ON to OFF after
*2. The maximum operating time is the time it takes the output to switch from OFF to ON after
*1. The maximum response time is the time it takes the output to switch from ON to OFF after
*2. The maximum operating time is the time it takes the output to switch from OFF to ON after
Case 1
Response Time from When D40A (1) Turns from ON to OFF until Safety Output (2) Turns from
ON to OFF
(
Case 2
Response Time from When D4NS Turns from ON to OFF until Safety Output (3) Turns from ON
to OFF
Non-contact Door Switch input
Logical AND input
Non-contact Door Switch input
Safety input
Logical AND input
20 ms
(D40A (1))
15 ms
(D4NS)
the input switches from ON to OFF.
the input switches from OFF to ON.
the input switches from ON to OFF.
the input switches from OFF to ON.
+
+
15 ms
(Logical AND
connection (1))
15 ms
(Logical AND
connection (1))
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
(excluding Expansion
(excluding Expansion
Max. response time
Max. response time
=
+
Units) *1
Units) *1
20 ms
15 ms
20 ms
15 ms
15 ms
35 ms
15 ms
(Logical AND
connection (2))
=
D40A/G9SX-NS
(excluding Expansion
(excluding Expansion
Max. operating time
Max. operating time
45 ms
Units) *2
Units) *2
100 ms
100 ms
100 ms
100 ms
50 ms
10