F39-EU1E Omron, F39-EU1E Datasheet - Page 642

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
I/O Circuit Diagrams
E3ZS
Circuit Diagrams (E3ZS-T81A with PNP Output)
Output mode: ON when light is incident (Light ON)
E3FS
Circuit Diagrams (E3FS-10B4@@@ with PNP Output)
Output mode: ON when light is incident (Light ON).
Receiver
Emitter
*1. When using in Safety Category 2 configurations, make sure all terminals on the
*2. Make sure to connect the pink wire (mode selection input 2) to 24 VDC.
*3. Make sure to connect to the 0V terminal when the E3ZS is not connected to an
Receiver
Emitter
*1. Make sure all terminals on the B1 Module of the F3SX are properly connected.
*2. Make sure to connect the pink wire (mode selection input 2) to 24 VDC.
*3. Make sure to connect to the 0V terminal when the E3FS is not connected to an
Note: The E3FS-10B4@@@ functions as a standalone Sensor when it is connected
B1 Module of the F3SX are properly connected. Do not connect the terminals to
another module. See the F3SX operation manual for details.
F3SX and the test input is not used.
Do not connect the terminals to another Module. See the F3SX operation manual
for details.
F3SX and the test input is not used.
as shown in the wiring diagram above. However, it is certified a Type 2 Safety
Sensor when it is properly connected to the B1 Module of the F3SX. This also
means it must be properly connected to an F3SX to use it as part of a safety
system.
http://www.ia.omron.com/
indicator
Stability
Lit when
Green
Green
ON
Orange
Orange
Orange
Emission
Lit when
Red
indicator
emitting
Operation
Lit when
indicator
OFF
Main
circuit
Main
circuit
circuit
circuit
Main
Main
I/O circuit
I/O circuit
Internal
resistance
of the output
IC
1
2
4
3
1
2
4
3
1
4
3
1
4
3
Brown
Brown
Pink
Black
Blue
Black
Brown
Brown
Pink
Blue
Pink
Blue
Pink
*3
*3
Blue
*2
*2
Connects to the 24 VDC
terminal.
Connects to the 0 V
terminal.
Connects to the 24 VDC
terminal.
Connects to the 0 V
terminal.
Connects to the control
output terminal.
Connects to the test input
terminal.
Connects to the control
output terminal.
Connects to the test input
terminal.
Connects to the 24 VDC
terminal.
Connects to the 0 VDC
terminal.
Connects to the 24 VDC
terminal.
Connects to the 0 V
terminal.
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Timing Charts
Output Modes and Timing Char
Emitter Timing Chart
Timing Charts
Output Modes and Timing Chart
Emitter Timing Chart
Note: The F3SX performs self-diagnosis
Control
output
Operation
indicator
(orange)
Operation
indicator
Light incident
Light interrupted
Test input
Emission
Light incident
Light interrupted
Operation
indicator
(orange)
Operation
indicator
(orange)
Control
output
Test input
Emission
every 20 ms.
Green
Red
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
E3ZS/E3FS
9