S25FL032P0XMFI011 Spansion Inc., S25FL032P0XMFI011 Datasheet - Page 45

no-image

S25FL032P0XMFI011

Manufacturer Part Number
S25FL032P0XMFI011
Description
IC 32M CMOS 3V 104MHZ SPI BUS INTERFACE
Manufacturer
Spansion Inc.
Datasheet

Specifications of S25FL032P0XMFI011

Cell Type
NOR
Density
32Mb
Access Time (max)
8ns
Interface Type
Serial (SPI)
Boot Type
Bottom/Top
Address Bus
1b
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
SOIC W
Sync/async
Synchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8b
Number Of Words
4M
Supply Current
38mA
Mounting
Surface Mount
Pin Count
8
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S25FL032P0XMFI011
Manufacturer:
SPANSION
Quantity:
4 391
Part Number:
S25FL032P0XMFI011
Manufacturer:
SPANSION
Quantity:
20 000
Company:
Part Number:
S25FL032P0XMFI011
Quantity:
664
Company:
Part Number:
S25FL032P0XMFI011
Quantity:
5 974
Part Number:
S25FL032P0XMFI0119
Manufacturer:
SPAN
Quantity:
6 142
9.18
October 5, 2009 S25FL032P_00_05
Bulk Erase (BE)
The Bulk Erase (BE) command sets all the bits within the entire memory array to logic 1s. A WREN command
is required prior to writing the BE command.
The host system must drive CS# low, and then write the BE command on SI. CS# must be driven low for the
entire duration of the BE sequence. The command sequence is shown in
on page
The host system must drive CS# high after the device has latched the 8th bit of the CE command, otherwise
the device does not execute the command. The BE operation begins as soon as CS# is driven high. The
device internally controls the timing of the operation, which requires a period of t
be read to check the value of the Write In Progress (WIP) bit while the BE operation is in progress. The WIP
bit is 1 during the BE operation, and is 0 when the operation is completed. The device internally resets the
Write Enable Latch to 0 before the operation completes (the exact timing is not specified).
The device only executes a BE command if all Block Protect bits (BP2:BP0) are 0 (see
on page
23.
18). Otherwise, the device ignores the command.
SO
CS#
SCK
SI
D a t a
Mode 3
Mode 0
Hi-Z
Figure 9.21 Bulk Erase (BE) Command Sequence
S h e e t
S25FL032P
0
1
2
Command
3
4
5
6
Figure 9.21
7
BE
. The Status Register may
and
Table 7.3
Table 9.1