Specifications of TLE6288RNT

Switch Type
High Side/Low Side
Power Switch Family
TLE 6288 R
Power Switch On Resistance
150mOhm
Number Of Outputs
6
Mounting
Surface Mount
Supply Current
10mA
Package Type
DSO
Operating Temperature (min)
-40C
Operating Temperature (max)
150C
Operating Temperature Classification
Automotive
Propagation Delay Time
200ns
Pin Count
36
Power Dissipation
800mW
Lead Free Status / RoHS Status
Compliant
4.1.2
Peak Current, Peak Time, Hold Current and fixed Off-Time can be set via SPI.
To avoid regulation disturbances by current transients during switching (e.g. caused by ESD capacitors at the
outputs) the current regulator has a “leading edge blanking” of typical 20 µs in all three regulation modes. After
turning on the DMOS (internally or externally) the current regulation circuit is deactivated for the first 20 µs. This
guarantees that switching of the DMOS itself or charging of small capacitors at the output (e.g. ESD) is not
disturbing the current regulation.
To detect shorted loads or low inductance loads in all three regulation modes a timer is started when a channel is
turned on (
depending on the configured current control mode) within this time a overload fault is reported (see
Figure 5
Data Sheet
Hold only: When the channel is turned on externally (SPI or parallel input) the current rises to the programmed
hold current level. Then the channel is internally turned off and a timer is started for a fixed off-time (e.g.
200 µs). After this time the channel is internally turned on again until the hold current level is reached again
and so on. This regulation works automatically until the channel is turned of externally.
Peak and hold mode with minimum peak time: When the channel is turned on the current rises to the
programmed peak current level. Then the channel is internally turned off, the current regulator changes to hold
current values and a timer is started for a constant off-time. After this time the channel is internally turned on
again until the hold current value is reached and then again turned off for the fixed off time. This regulation
works automatically until the channel is turned of externally.
Peak and hold mode with programmed peak time: When the channel is turned on the current rises to the
programmed peak current level. Then the channel is internally turned off and a timer is started for a fixed off-
time. After this time the channel is internally turned on again until the peak current value is reached and then
again turned off. This works until the programmed peak time is over. Then the current regulator changes to
hold current values and works as described under “hold only”.
t
li
). If the first rising edge of the load current reaches the programmed current level (peak or hold current
Current Regulator: Peak Current Control with Fixed Off-Time