BTS441RGXT Infineon Technologies, BTS441RGXT Datasheet

BTS441RGXT

Manufacturer Part Number
BTS441RGXT
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of BTS441RGXT

Lead Free Status / Rohs Status
Compliant
Smart Highside Power Switch
One Channel: 20mΩ
Status Feedback
Product Summary
General Description
Application
Basic Funktions
Protection Functions
Diagnostic Function
Infineon Technologies AG
On-state Resistance
Operating Voltage
Nominal load current
Current limitation
N channel vertical power FET with charge pump, ground referenced CMOS compatible input, monolithically
integrated in Smart SIPMOS ® technology.
Providing embedded protective functions.
All types of resistive, inductive and capacitve loads
Most suitable for loads with high inrush currents, so as lamps
Replaces electromechanical relays, fuses and discrete circuits
Very low standby current
Optimized static electromagnetic compatibility (EMC)
µC and CMOS compatible
Fast demagnetization of inductive loads
Stable behaviour at undervoltage
Short circuit protection
Current limitation
Overload protection
Thermal shutdown
Overvoltage protection (including load dump) with external
GND-resistor
Reverse battery protection with external GND-resistor
Loss of ground and loss of V bb protection
Electrostatic discharge (ESD) protection
Diagnostic feedback with open drain output
Open load detection in OFF-state
Feedback of thermal shutdown in ON-state
C compatible power switch for 5V, 12 V and 24 V DC applications
R ON
V bb(on)
I L(ISO)
I L(lim)
20m
4.75 ... 41V
21A
65A
1
Package
TO-263-5-2
SMD
ST
IN
PROFET
TO-220-5-12
protection
functions
Vbb
Logic
with
Straight
GND
BTS 441 R
2003-Oct-01
OUT
Load

Related parts for BTS441RGXT

BTS441RGXT Summary of contents

Page 1

... Reverse battery protection with external GND-resistor Loss of ground and loss protection Electrostatic discharge (ESD) protection Diagnostic Function Diagnostic feedback with open drain output Open load detection in OFF-state Feedback of thermal shutdown in ON-state Infineon Technologies AG Package TO-263-5-2 20m 4.75 ... 41V 21A 65A SMD ...

Page 2

... Input, activates the power switch Positive power supply voltage Diagnostic feedback, low on failure 5 OUT Positive power supply voltage Tab V bb Infineon Technologies AG current limit gate control + charge logic pump inductive load temperature sensor Open load detection Function Logic ground case of logical high signal ...

Page 3

... V is setup without the DUT connected to the generator per ISO 7637-1 and DIN 40839 Load dump the maximum inductive switch off energy AS 5) Device on 50mm*50mm*1.5mm epoxy PCB FR4 with 6cm connection. PCB is vertical without blown air. Infineon Technologies 13 150°C const. C ...

Page 4

... IN Operating current (Pin not subject to production test, specified by design 7) see also V in table of protection functions and circuit diagram page 7 ON(CL) 8) Measured with load, typ. 40 µA when no load in off 9) Add > 0, add Infineon Technologies AG Symbol ); T =25 ° =150 ° L(ISO) I L(GNDhigh 90 OUT ...

Page 5

... Note that the power dissipation is higher compared to normal operating conditions due to the voltage drop across the intrinsic drain-source diode. The temperature protection is not active during reverse current operation! Input and Status currents have to be limited (see max. ratings page 1 and circuit page 7). Infineon Technologies AG Symbol =-40° ...

Page 6

... L = "Low" Level H = "High" Level 14) External pull up resistor required for open load detection in off state 15 ground resistor R is used, add the voltage drop across this resistor. GND 16 potential at the Output exceeds the OpenLoad detection voltage Infineon Technologies AG 14) V 15) R see circuit page 0 ...

Page 7

... ESD zener diodes are not to be used as voltage clamp at DC conditions. Operation in this mode may resul a drift of the zener voltage (increase V). Inductive and overvoltage output clamp V Z PROFET GND V clamped typ. ON Infineon Technologies AG Overvolt. and reverse batt. protection OUT OUT V = 6.1 V typ., V ...

Page 8

... Consider at your PCB layout that in the case of Vbb dis- connection with energized inductive load all the load current flows through the GND connection. Infineon Technologies AG Inductive load switch-off energy dissipation E OUT ...

Page 9

... Typ. on-state resistance high Typ. standby current 9...34 V, IN1,2 = low bb(off bb(off - 100 Infineon Technologies 150°C 25°C -40° [V] bb 150 200 T [°C] j Page 9 BTS 441 R 2003-Oct-01 ...

Page 10

... OUT ST open drain proper turn on under all conditions Figure 2a: Switching a resistive load, turn-on/off time and slew rate definition OUT 90 dV/dton 10 Infineon Technologies AG Figure 2b: Switching a lamp OUT Figure 3a: Short circuit shut down by overtemperature, reset by cooling IN other channel: normal operation I dV/dtoff L I L(lim) ...

Page 11

... Figure 4a: Overtemperature: Reset if T < OUT T J Figure 5a: Open load: detection in OFF-state, turn on/off to open load IN1 t off V OUT1 delay 500µs ST delay Open load detection requires an external pull up resistor between OUT and V BB Infineon Technologies BTS 441 R 2003-Oct-01 ...

Page 12

... Office. Q67060-S6119 Infineon Technologies Components may only be used in life- support devices or systems with the express written approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life- support device or system affect the safety or B effectiveness of that device or system. Life support devices 4 ...

Related keywords