TLE6220GPNT Infineon Technologies, TLE6220GPNT Datasheet
TLE6220GPNT
Specifications of TLE6220GPNT
Related parts for TLE6220GPNT
TLE6220GPNT Summary of contents
Page 1
... Robotic controls General Description Quad Low-Side Switch in Smart Power Technology (SPT) with a Serial Peripheral Interface (SPI) and four open drain DMOS output stages. The TLE 6 220 GP is protected by embedded protection functions and designed for automotive and industrial applications. The output stages can be controlled d irect in parallel for PWM applications (injector coils), or through serial control via the SPI ...
Page 2
Pin Description Pin Symbol 1 GND 2 IN2 3 OUT1 Power Output Channel RESET PRG Program (inputs high or low active) 8 OUT2 Power Output Channel 2 9 IN1 10 GND 11 GND ...
Page 3
Maximum Ratings for T j Parameter Supply Voltage Continuous Drain Source Voltage (OUT1...OUT4) Input Voltage, All Inputs and Data Lines Load Dump Protection =13.5 V Load Dump With Automotive Injector Valve ...
Page 4
... Current Limitation; Overload Threshold Current Overtemperature Shutdown Threshold 6 Hysteresis 4 For V < 4.5V the power stages are switched according the input signals and data bits or are definitely S switched off. This undervoltage reset gets active Reset = L the supply current is reduced to typ. 20µA 6 This parameter will not be tested but guaranteed by design V2 ...
Page 5
Electrical Characteristics cont. Parameter and Conditions V = 4 ° 150 °C ; Reset = (unless otherwise specified) 5. Diagnostic Functions Open Load Detection Voltage Output Pull ...
Page 6
... Functional Description The TLE 6220 quad-low-side power switch which provides a serial peripheral interface (SPI) to control the 4 power DMOS switches, as well as diagnostic feedback. The power transi s - tors are protected against short active zener clamp. The diagnostic logic recognises a fault condition which can be read out via the serial diagnostic output (SO) ...
Page 7
... Reset pin. If the reset pin logic low state, it clears the SPI shift regi s ter and switches all outputs OFF. An internal pull-up structure is provided on chip. As long as the reset pin is low the device is in low quiescent current mode and the supply current is reduced to typ. ...
Page 8
Serial Control of the Outputs: SPI protocol Each output is independently controlled by an output latch and a common reset line, which ables all four outputs. The Serial Input (SI) is read on the falling edge of ...
Page 9
... Serial Input, data bits 0...3 This OR operation enables the serial interface to switch the channel ON, even though the cor- responding parallel input might be in the off state. Also parallel control of the outputs is possible without an SPI input. The OR-function is the default Boolean operation if the device restarts after a Reset, or when the supply voltage is switched on for the first time ...
Page 10
... The next command is now: LHHH HHLH LHHH as command word has no special meaning but it will be accepted operation and the data bits will be ORed with the inputs and the outputs 1,3 and 4 will be switched on. See above: 'If the OR operation is programmed it is latched until it is overwritten by the AND operation ...
Page 11
Diagnostics FAULT - Fault pin. There is a general fault pin (open drain) which shows a high to low transi- tion as soon as an error occurs for any one of the four channels. This fault indication can be used ...
Page 12
CS SCLK Control Bits 6 4444 7 4444 MSB Outputs Figure 2: Serial Interface Figure 3: Input Timing Diagram CS 0 SCKH t lead SCLK Figure 4: 0.7 ...
Page 13
80% 20% Figure 5: Power Outputs Application Circuit VS µC e.g. C166 MTSR MRST CLK P xy V2.1 Data Sheet TLE 6220 OFF 10k VS PRG OUT1 FAULT ...
Page 14
Typical electrical Characteristics Drain-Source on-resistance DS(ON Typical Drain- Source ON-Resistance 0,58 0,53 0,48 0,43 0,38 0,33 0,28 0,23 -50 -25 0 Figure 6 : Typical ON Resistance versus Junction-Temperature ...
Page 15
... Parallel SPI Configuration Engine Management Application TLE 6230 GP in combination with TLE 6240 GP (16-fold switch) for relays and general purpose loads and TLE 6220 GP (quad switch) to drive the injector valves. This arrangement covers the numerous loads to be driven in a modern Engine Management/Powertrain system. From 28 channels in sum 16 can be controlled direct in parallel for PWM applications ...
Page 16
Package and Ordering Code (all dimensions in mm DSO - Ordering Code Q67006-A9315 TLE 6220 13.7 -0 1.43 1.27 20 ...
Page 17
Green Product (RoHS compliant) To meet the world-wide customer requirements for environmentally friendly products and to be compl i ant with government regulations the device is available as a green product. Green products are RoHS- Compliant (i.e Pb-free finish on ...
Page 18
Revision History Version Date Changes V2.0 -> 20.05.03 Ordering Code removed V2.1 V1.1 -> 20.04.2007 Green Date sheet Version created V2.0 V2.0 20.04.2007 Changes to Green Product Version: V2.0 -> 05.04.2007 Layout Changes, correct green package name implemented P-DSO-36- 12 ...
Page 19
... Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express writ- ten approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life-support device or system or to affect the safety or effectiveness of that device or system. ...