TLE6251G Infineon Technologies, TLE6251G Datasheet - Page 14
TLE6251G
Manufacturer Part Number
TLE6251G
Description
IC TXRX CAN STD HI SPEED 8SOIC
Manufacturer
Infineon Technologies
Type
Transceiverr
Datasheet
1.TLE6251G.pdf
(31 pages)
Specifications of TLE6251G
Package / Case
8-SOIC (3.9mm Width)
Number Of Drivers/receivers
1/1
Protocol
CAN
Voltage - Supply
4.75 V ~ 5.25 V
Mounting Type
Surface Mount
Product
Controller Area Network (CAN)
Number Of Transceivers
1
Data Rate
1 MBd
Supply Voltage (max)
5.25 V
Supply Voltage (min)
4.75 V
Supply Current (max)
10 mA
Maximum Operating Temperature
+ 150 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
SP000082094
TLE6251GNT
TLE6251GT
TLE6251GT
TLE6251GNT
TLE6251GT
TLE6251GT
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE6251G
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
•
•
Wake-Up Flag
•
•
•
Wake-Up Source Flag
•
•
•
Bus Failure Flag
•
•
•
Local Failure Flag
•
•
•
Final Data Sheet
Indicator: NERR = LOW in RxOnly mode
Remarks: Power-up flag is cleared when entering the normal mode
Task: to signalize a wake-up condition at the WK pin (filtering time
message (filtering time
Indicator: RxD or NERR = LOW in sleep/stand-by mode immediately after wake-up
Remarks: Flag is cleared on entering the RxOnly mode
Task: to distinguish between the two wake-up sources
Indicator: NERR = LOW in normal mode = wake-up via WK pin
Remarks: only available if the power-up flag is cleared. After four recessive to dominant
edges on TxD in normal mode, the flag is cleared. Leaving the normal mode clears the wake-
up source flag.
Task: to signalize a bus line short circuit condition to GND,
Indicator: NERR = LOW in normal mode
Remarks: flag is set after four consecutive recessive to dominant cycles on pin TxD when
trying to drive the bus dominant. The bus failure flag is cleared if the normal mode is
reentered or 4 recessive to dominant edges at TxD without failure condition.
Task: to signalize one of the five local failure conditions described in
and -Detection
Indicator: NERR = LOW in RxOnly mode (local failure flag is set)
Remarks: the flag is cleared when entering the normal mode from RxOnly mode or when RxD
is dominant while TxD is recessive.
t
>
t
WU
)
14
V
S
or
V
CC
t
>
Local Failure-Flags
t
WK
Rev. 3.2, 2006-04-05
) or via CAN bus
TLE 6251 G