N25Q064A13EF640F Micron Technology Inc, N25Q064A13EF640F Datasheet - Page 45

no-image

N25Q064A13EF640F

Manufacturer Part Number
N25Q064A13EF640F
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of N25Q064A13EF640F

Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
N25Q064A13EF640F
Manufacturer:
MICRON
Quantity:
1 001
Part Number:
N25Q064A13EF640F
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
N25Q064A13EF640F
Manufacturer:
MICRON/镁光
Quantity:
20 000
Part Number:
N25Q064A13EF640F
0
N25Q064 - 3 V
Table 9.
Table 10.
0
0
1
1
0
0
0
0
Lock Down
TB bit BP3 Bit BP2 Bit BP1 Bit BP0 Bit
Sector Lock Register
bit
0
0
0
0
Status Register Content
The Lock Registers can be read and written using the Read Lock Register (RDLR) and
Write to Lock Register (WRLR) instructions.
In each Lock Register two bits control the protection of each sector: the Write Lock bit and
the Lock Down bit.
The definition of the Lock Register bits is given in Table 9: Lock Register out.
SPM2
The second software protected mode (SPM2) uses the Block Protect bits (BP3, BP2, BP1,
BP0) and the Top/Bottom bit (TB bit) to allow part of the memory to be configured as read-
only. See
Software protection truth table (Sectors 0 to 127, 64 Kbyte granularity)
As a second level of protection, the Write Protect signal (applied on the W/VPP pin) can
freeze the Status Register in a read-only mode. In this mode, the Block Protect bits (BP3,
BP2, BP1, BP0) and the Status Register Write Disable bit (SRWD) are protected.
Protected area sizes (TB bit = 0)
0
1
0
1
Write Lock
0
0
0
0
bit
Write Lock bit: The Write Lock bit determines whether the contents of the sector can be
modified (using the Write, Program, or Erase instructions). When the Write Lock bit is
set to '1', the sector is write protected - any operations that attempt to change the data
in the sector will fail. When the Write Lock bit is reset to '0', the sector is not write
protected by the Lock Register, and may be modified.
Lock Down bit: The Lock Down bit provides a mechanism for protecting software data
from simple hacking and malicious attack. When the Lock Down bit is set to '1', further
modification to the Write Lock and Lock Down bits cannot be performed. A powerup is
required before changes to these bits can be made. When the Lock Down bit is reset to
'0', the Write Lock and Lock Down bits can be changed.
Section 16: Ordering
0
0
1
1
Sector unprotected from Program/Erase/Write operations, protection status reversible.
Sector protected from Program/Erase/Write operations, protection status reversible.
Sector unprotected from Program/Erase/Write operations.
Sector protection status cannot be changed except by a power-up.
Sector protected from Program/Erase/Write operations.
Sector protection status cannot be changed except by a power-up.
0
1
0
1
None
Upper 128th
Upper 64th
Upper 32nd
information.
Protected Area
Micron Technology, Inc., reserves the right to change products or specifications without notice.
Protection Status
Memory Content
All sectors
Sectors 0 to 126
Sectors 0 to 125
Sectors 0 to 123
©2010 Micron Technology, Inc. All rights reserved.
Unprotected Area
Protection modes
45/150