XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 313

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
Analog Outputs
7-10-6 Application Example
Outputting the Analog
Output Value Stored
in the Auxiliary Area
Outputting a Stepped
Analog Output
Outputting a Sloped
Analog Output
286
In this example, the Motion Control Module outputs the analog output value
stored in A810 from analog output 1.
Set the following System Setup settings:
In this example, the Motion Control Module outputs a step-pattern analog out-
put using a particular input signal as the trigger.
Set the following System Setup settings:
In this example, the Motion Control Module outputs a sloped analog output
using a particular input signal as the trigger.
Set the following System Setup settings:
• Set the output value in A810 or A811 with an instruction such as MOV.
• Execute SPED(885) or ACC(888).
• Analog Input/Output Tab Page
• Analog Input/Output Tab Page
• Analog Input/Output Tab Page
• Analog Input/Output Tab Page
• Analog Input/Output Tab Page
• Analog Input/Output Tab Page
0002.01
log output 1 to “1 to 5 V.”
ing method to END refresh.
log output 1 to “1 to 5 V.”
ing method to immediate refresh.
log output 1 to “1 to 5 V.”
ing method to immediate refresh.
0002.01
D00000
0
3
E
@SPED
8
@MOV
D00000
SET
Specified analog output value = 03E8 hex
(1,000 decimal = 25%)
#0001
#0000
A814.00
#1000
Output 1: Set the output range of ana-
Output 1: Set the output range of ana-
Output 1: Set the output range of ana-
Output: Set the analog output refresh-
Output: Set the analog output refresh-
Output: Set the analog output refresh-
A810
When CIO 0002.01 goes ON, SPED is
executed to output a stepped analog
signal from analog output port 1, with an
output range of 1 to 5 V, and an analog
output value of 03E8 hex (25% = 2 V).
When CIO 0002.01 goes ON, MOV
stores 1000 hex in A810 (Analog
Output 1 Output Value).
Turns ON A814.00 (Analog Output 1
Conversion Enable Bit).
Section 7-10