XW2Z-200J-B9 Omron, XW2Z-200J-B9 Datasheet - Page 79

no-image

XW2Z-200J-B9

Manufacturer Part Number
XW2Z-200J-B9
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B9

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB9
List of Models
2-1
2-2
General Specifications
52
Coordinator Mod-
ule
Motion Control
Modules
End Module
(FQM1 Rack)
I/O Control Module ---
I/O Interface Unit
End Cover
Servo Relay Units
FQM1 Flexible
Motion Controller
Set
Programming
Device
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Ambient operating tem-
perature
Ambient operating
humidity
Atmosphere
Ambient storage temper-
ature
Grounding
Enclosure
Name
List of Models
General Specifications
Item
Standard
(with built-in I/O)
Pulse I/O
Analog I/O
Standard
---
Standard
---
Set for pulse I/O
Set for analog I/O FQM1S-MC224
CX-Programmer
Ver. 6.11 or later
Type
20 M
2,300 V AC 50/60 Hz for 1 min between AC external and GR terminals (See notes 1 and 2.)
Leakage current: 10 mA max.
720 V AC 50/60 Hz for 1 min between DC external and GR terminals (See note 1.)
Leakage current: 10 mA max.
2 kV on power supply line (conforming to IEC61000-4-4)
10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s
tions for 80 minutes total (Time coefficient: 8 minutes
min.) (conforming to JIS C0040)
147 m/s
0 to 55 C
10% to 90% (with no condensation)
Must be free from corrosive gases
Less than 100
Mounted in a panel.
20 to 75 C
min. (at 500 VDC) between AC external and GR terminals (See note 1.)
2
3 times each in X, Y, and Z directions (conforming to JIS C0041)
FQM1-CM002
FQM1-MMP22
FQM1-MMA22
FQM1-TER01
FQM1-IC101
CJ1W-II101
CJ1W-TER01
XW2B-80J7-1A
FQM1S-MC233
WS02-CXPC1-E-V6
Model
Program capacity: 10 Ksteps
16 general-purpose inputs, 8 general-purpose outputs
Peripheral port, RS-232C port, RS-422A port
Program capacity: 10 Ksteps
2 pulse inputs, 2 pulse outputs, 12 general-purpose
inputs, 8 general-purpose outputs
Program capacity: 10 Ksteps
2 pulse inputs, 1 analog input, 2 analog outputs,
12 general-purpose inputs, 8 general-purpose outputs
Connects to the right end of the FQM1.
Use to connect CJ-series Units to the FQM1. (This
includes connection of an Expansion Rack.)
Use to connect an Expansion Rack.
The I/O Interface Unit connects to the right side of the
Expansion Rack’s Power Supply Unit.
Connects to the right end of the Expansion Rack. Also
connects to the right end of the FQM1 Rack if an I/O Con-
trol Module is being used.
Simplifies wiring from the Motion Control Module to two
Servo Drivers, wiring for all switches, sensors, and other
general-purpose I/O, and wiring the RS-422A line.
A set including the CJ1W-PA202, FQM1-CM002, FQM1-
MMP22, and FQM1-TER01
A set including the CJ1W-PA205R, FQM1-CM002,
FQM1-MMA22, and FQM1-TER01
Used for System Setup setting, programming, and moni-
toring for Coordinator Modules and Motion Control Mod-
ules.
Specifications
coefficient factor 10 = total time 80
Specifications
2
in X, Y, and Z direc-
Section 2-1