AD9979BCPZ Analog Devices Inc, AD9979BCPZ Datasheet - Page 29

IC PROCESSOR CCD 14BIT 48-LFCSP

AD9979BCPZ

Manufacturer Part Number
AD9979BCPZ
Description
IC PROCESSOR CCD 14BIT 48-LFCSP
Manufacturer
Analog Devices Inc
Type
CCD Signal Processor, 14-Bitr
Datasheet

Specifications of AD9979BCPZ

Input Type
Logic
Output Type
Logic
Interface
3-Wire Serial
Current - Supply
48mA
Mounting Type
Surface Mount
Package / Case
48-LFCSP
Supply Voltage Range
1.6V To 2V, 1.6V To 3.6V, 2.7V To 3.6V
Operating Temperature Range
-25°C To +85°C
Digital Ic Case Style
LFCSP
No. Of Pins
48
Svhc
No SVHC (18-Jun-2010)
Package /
RoHS Compliant
Ic Function
14-bit CCD Signal Processor With Precision Timing Core
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9979BCPZ
Manufacturer:
ADI
Quantity:
1 095
Part Number:
AD9979BCPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD9979BCPZRL
Manufacturer:
VISHAY
Quantity:
4 276
GP1_PROTOCOL 0
Single-Field Toggles
Single-field toggles begin in the field following the register write.
There can be up to two toggles in the field. The mode is set with
GPx_PROTOCOL equal to 1. In this mode, the field toggle
settings must be set to 1. Toggles repeat for each field until
GPx_PROTOCOL is set to 0. GPx_PROTOCOL must be reset
to 0 for one field before it can be active again.
Preparation
The GP toggle positions can be programmed any time prior to
use. For example,
Details
Scheduled Toggles
Scheduled toggles are programmed to occur during any upcoming
field. For example, there can be one toggle in Field 1 and the next
toggle in Field 3. The mode is set with GPx_PROTOCOL = 2,
which tells the GPO to obey the primary field counter.
Preparation
The GP toggle positions can be programmed any time prior to
use. For example,
Details
0x054 ←
0x055 ←
0x056 ←
A) Field 0: 0x052 ← 0x0000001
B) Field 1: 0x052 ← 0x0000000
0x054 ← 0x00C4002
0x055 ← 0x0004000
0x056 ← 0x00000B3
A) Field 0: 0x050 ← 0x0000001
REG WRITE
Figure 36. Single-Field Toggles Using GP1_PROTOCOL = 1
GPO1
VD
NOTES
1. THE FIELD TOGGLE POSITION IS IGNORED WHEN THE GPO
PROTOCOL IS 1.
TOGGLE POSITIONS REPEAT FOR EACH FIELD UNTIL
GPO PROTOCOL IS RESET.
0x000A001
0x0002000
0x000000F
0x052 ← 0x0000002
A
1
B
1
0
2
Rev. C | Page 29 of 56
RapidShot Sequences
RapidShot technology provides continuous repetition of scheduled
toggles. As in the case of scheduled toggles, a pulse can traverse
multiple fields. The mode is set with GPx_PROTOCOL = 3,
which tells the GPO to obey the repeating primary field counter.
GPx_PROTOCOL must be reset to 0 for one field before it can
be active again.
Preparation
The GPO toggle positions can be programmed any time prior
to use. For example,
Details
GP1_PROTOCOL 0
GP1_PROTOCOL 0
0x051 ← 0x0000002
0x054 ← 0x000A001
0x055 ← 0x0004000
0x056 ← 0x000000F
0x052 ← 0x0000003
A) Field 0: 0x050 ← 0x0000002
B) Field 2: 0x050 ← 0x0000007
REG WRITE
REG WRITE
Figure 38. RapidShot Toggle Operation Using GP1_PROTOCOL = 3
PRIMARY
PRIMARY
COUNT
COUNT
GPO1
Figure 37. Scheduled Toggles Using GP1_PROTOCOL = 2
GPO1
VD
VD
NOTES
1. THE GPO PROTOCOLS ARE THE SAME AS THE SCHEDULED
THE PRIMARY COUNTER REGULATES THE SUBCK
AND VSG ACTIVITY. LINK A GPO TO THE PRIMARY COUNTER
ONLY IF IT IS TO HAPPEN DURING EXPOSURE/READ.
TOGGLES, EXCEPT THE TOGGLES CAN BE EXCLUDED FROM
REPETITION BY CHOOSING GPO PROTOCOL 2.
CAUTION! THE FIELD COUNTER MUST BE FORCED INTO IDLE
STATE TO TERMINATE REPETITIONS.
0
0 (IDLE)
(IDLE)
A
A
3
1
1
1
2
2
2
1
1
3
2
2
4
2
TERMINATED
AT VD EDGE
1
AD9979
0
5
B
0